Improving peak concentrations of a single dose regime of gentamicin in patients with sepsis in the emergency department

To achieve an optimal effect in patients with sepsis at the emergency department (ED), the gentamicin peak-concentration should be sufficiently high (i.e. peak-concentration/MIC ≥8-10). ICU patients with sepsis often need higher gentamicin doses to achieve sufficiently high peak-concentrations. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2019-01, Vol.14 (1), p.e0210012-e0210012
Hauptverfasser: Cobussen, Maarten, Stassen, Patricia M, Posthouwer, Dirk, van Tiel, Frank H, Savelkoul, Paul H M, Havenith, Thomas, Haeseker, Michiel B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To achieve an optimal effect in patients with sepsis at the emergency department (ED), the gentamicin peak-concentration should be sufficiently high (i.e. peak-concentration/MIC ≥8-10). ICU patients with sepsis often need higher gentamicin doses to achieve sufficiently high peak-concentrations. The aim of this study is to investigate which dose is needed to reach adequate peak-concentrations in patients presenting with sepsis at the ED. Patients with sepsis at the ED were included from August 2015 until February 2017. Peak-concentrations were measured in blood 30 minutes after the first gentamicin dose. The study consisted of three phases. In the first phase, peak-concentrations were measured after a standard dose of 5mg/kg. In the second phase, a simulation ((peak-concentration/actual dose) × simulated dose) was performed to determine which dose was needed to reach adequate gentamicin peak-concentrations of ≥16mg/L. In the third phase, peak-concentrations were measured for the best simulated dose. In phase one, of 86 patients who received a dose of 5mg/kg, 34 (39.5%) patients did not reach the target peak-concentration of ≥16mg/L, and 73 (84.9%) did not reach ≥20mg/L. In phase two, the simulation showed that with a dose of 7mg/kg 83 (96.5%) patients would reach peak-concentrations ≥16mg/L, and 67 (77.9%) of ≥20mg/L. In phase three, 53 patients received a dose of 7mg/kg, of whom 45 (84.9%) reached peak-concentrations of ≥16mg/L, and 31 (58.5%) of ≥20mg/L. Patients with sepsis at the ED need higher doses of gentamicin. A dose of 7mg/kg is needed to achieve adequate peak-concentrations in the majority of patients.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0210012