Assessing subcutaneous adipose tissue by simple and portable field instruments: Skinfolds versus A-mode ultrasound measurements

This study compared subcutaneous adipose tissue (SAT) measurements using a skinfold caliper and Renco Lean-Meater Series 12 A-mode portable ultrasound scanner (A-US). It aimed to assess their inter- and intra-rater reliability and measure the agreement between both methods. Eighty-four volunteers of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2018-11, Vol.13 (11), p.e0205226-e0205226
Hauptverfasser: Pérez-Chirinos Buxadé, Carla, Solà-Perez, Toni, Castizo-Olier, Jorge, Carrasco-Marginet, Marta, Roy, Alex, Marfell-Jones, Michael, Irurtia, Alfredo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study compared subcutaneous adipose tissue (SAT) measurements using a skinfold caliper and Renco Lean-Meater Series 12 A-mode portable ultrasound scanner (A-US). It aimed to assess their inter- and intra-rater reliability and measure the agreement between both methods. Eighty-four volunteers of different fitness levels were divided into three groups by Ʃ6 skinfolds: G1 ≤ 55 mm (n = 33 males); G2 > 55 mm (n = 32 males); G3 = 98.0 ± 52.3 mm (n = 19 females). Triceps, subscapular, biceps, iliac crest, supraspinal, abdominal, front thigh and medial calf were assessed by ultrasound and skinfolds. Two technicians for both tools performed triplicate measures. Intraclass correlation (ICC), technical error of measurement (TEM) and coefficients of variation (CVs) were applied for test-retest and inter-rater reliability. Non-Parametric statistics were used in order to establish possible statistical differences and correlation between skinfolds thickness and uncompressed subcutaneous adipose tissue thickness from ultrasound. The amount of agreement between both methods was assessed with Lin's coefficient and a scatterplot of all site locations. A Bland-Altman plot was constructed to establish limits of agreement between groups and regression analysis was employed to assess the ability of skinfolds to explain the variance of ultrasound. Test-retest ICC for skinfolds and ultrasound were higher than 0.989 and 0.793, respectively. Inter-rater ICC for skinfolds was 0.999 with a 95% CI of 0.995 to 0.999 and for ultrasound was 0.755 with a much larger 95% CI of 0.622 to 0.841. TEMs (> 8.50%) and CVs (> 6.72%) compromised ultrasound reliability. Statistical differences were found in most of the analysed anatomical sites (p < 0.001) except in biceps G2 (Z = -1.150, p = 0.25) and G3 (Z = -1.309, p = 0.19). Good correlations (r > 0.7, p ≤ 0.05) were reported at almost all anatomical sites and groups except for biceps (G1: Rho = 0.26, p = 0.140) and abdominal (G2: Rho = -0.16, p = 0.38; G3: Rho = 0.43, p = 0.068). Lin's concordance correlation coefficient registered low values of agreement between skinfolds and A-mode ultrasound (ranged from-0.009-0.646). The scatterplot and the estimated regression line drawn through the midst of all anatomical sites of the whole sample had a slope of 0.51 and R2 adjusted = 0.62 was obtained. The combined analysis between the Bland-Altman plot and the linear regression showed that specifically in the G2 and G3 groups, as the SAT increases t
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0205226