Frame-based stereotactic biopsies using an intraoperative MR-scanner are as safe and effective as conventional stereotactic procedures

Frame-based stereotactic biopsy (FBSB) is a minimally-invasive and effective procedure for the diagnosis of brain lesions and will likely gain clinical importance. Since FBSB procedures comprise a variety of imaging and sampling methods, it is necessary to compare the safety and effectiveness of ind...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2018-10, Vol.13 (10), p.e0205772-e0205772
Hauptverfasser: Neumann, Jan-Oliver, Campos, Benito, Younes, Bilal, Jakobs, Martin, Jungk, Christine, Beynon, Christopher, Deimling, Andreas von, Unterberg, Andreas, Kiening, Karl
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Frame-based stereotactic biopsy (FBSB) is a minimally-invasive and effective procedure for the diagnosis of brain lesions and will likely gain clinical importance. Since FBSB procedures comprise a variety of imaging and sampling methods, it is necessary to compare the safety and effectiveness of individual techniques. To assess the safety and effectiveness of FBSB using 1.5T iMRI as a one-stop procedure under general anesthesia without intraoperative histological examination. In this single-center, retrospective analysis, 500 consecutive FBSBs using iMRI were compared to a historic control of 100 biopsies with traditional workflows (computed tomography (CT) with MRI image fusion). All procedures were performed under general anesthesia. Data on surgical procedures, pre- and postoperative neurologic patient status, complications and diagnostic yield were extracted from clinical records. Complication rates and diagnostic yield showed no significant differences between both groups. Mortality was 0.6%, 95% CI = [0.12%, 1.74%], in the iMRI and 0.0% [0.00%, 3.62%], in the control group with a morbidity of 5.4% [3.6%, 7.8%] and 6.0% [2.2%, 12.6%] and a diagnostic yield of 96.8% [94.9%, 98.2%] and 96.0% [90.1%, 98.9%]. Mean procedure duration was 124 [121, 127] minutes using iMRI and 112 [106, 118] minutes in the control group. FBSB using 1.5T iMRI under general anesthesia is a safe and effective procedure and is equivalent to traditional stereotactic workflows with respect to complication rate and diagnostic yield.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0205772