Functional and Prognostic Implications of the Main Pulmonary Artery Diameter to Aorta Diameter Ratio from Chest Computed Tomography in Korean COPD Patients

The ratio of the diameter of the main pulmonary artery (mPA) to the diameter of the aorta (Ao) on chest computed tomography is associated with diverse clinical conditions. Herein, we determined the functional and prognostic implications of the mPA/Ao ratio in Korean chronic obstructive pulmonary dis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2016-05, Vol.11 (5), p.e0154584-e0154584
Hauptverfasser: Chung, Kyung Soo, Kim, Young Sam, Kim, Se Kyu, Kim, Ha Yan, Lee, Sang Min, Seo, Joon Beom, Oh, Yeon Mok, Jung, Ji Ye, Lee, Sang-Do
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The ratio of the diameter of the main pulmonary artery (mPA) to the diameter of the aorta (Ao) on chest computed tomography is associated with diverse clinical conditions. Herein, we determined the functional and prognostic implications of the mPA/Ao ratio in Korean chronic obstructive pulmonary disease (COPD) patients. The study population comprised 226 chronic obstructive pulmonary disease patients from the Korean Obstructive Lung Disease cohort who underwent chest computed tomography. We analyzed the relationships between the clinical characteristics, including pulmonary function, echocardiography findings, St. George's Respiratory Questionnaire, 6-minute walking (6MW) distance, and exacerbation with the mPA, Ao, and mPA/Ao ratio. The mean age was 65.8 years, and 219 (96.9%) patients were male. The mean FEV1% predicted and FEV1/FVC ratio were 61.2% and 47.3%, respectively. The mean mPA and Ao were 23.7 and 36.4 mm, respectively, and the mPA/Ao ratio was 0.66. The mPA/Ao ratio correlated negatively with the 6MW distance (G = -0.133, P = 0.025) and positively with the right ventricular pressure (G = 0.323, P = 0.001). After adjustment for potential confounders, the mPA/Ao ratio was significantly associated with 6MW distance (β = -107.7, P = 0.017). Moreover, an mPA/Ao ratio >0.8 was a significant predictor of exacerbation at the 1-year (odds ratio 2.12, 95% confidence interval 1.27-3.52) and 3-year follow-ups (odds ratio 2.04, 95% confidence interval 1.42-2.90). The mPA/Ao ratio is an independent predictor of exercise capacity and an mPA/Ao ratio >0.8 is a significant risk factor of COPD exacerbation.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0154584