Interferometric determination of the refractive index of liquid sulphur dioxide

The absolute refractive index of liquid sulphur dioxide (SO(sub2)) was determined with an uncertainty of +or-0.0007 with a Michelson interferometer and a computer-controlled rotatory stage supporting a rectangular fused silica cell containing the liquid. The measurements were performed at temperatur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement science & technology 2000-12, Vol.11 (12), p.1714-1720
Hauptverfasser: Musso, M, Aschauer, R, Asenbaum, A, Vasi, C, Wilhelm, Emmerich
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The absolute refractive index of liquid sulphur dioxide (SO(sub2)) was determined with an uncertainty of +or-0.0007 with a Michelson interferometer and a computer-controlled rotatory stage supporting a rectangular fused silica cell containing the liquid. The measurements were performed at temperatures around 20\0\C for the laser line wavelengths 632.8, 514.5 and 488.0 nm. The experimental data were fitted to the simple Cauchy dispersion formula. The results calculated from this formula are consistent within the experimental uncertainty with published values obtained at other wavelengths and/or other temperatures. (Original abstract)
ISSN:0957-0233
1361-6501
DOI:10.1088/0957-0233/11/12/310