Sensitive Determination of Cisplatin in Body Fluids with HPLC and On-Line Reductive Electrochemical Detection

A sensitive method for the determination of the antitumor agent cisplatin has been developed consisting of solvent-generated anion exchange chromatography and on-line reductive electrochemical detection. CDDP was retained on a hexadecyl-trimethylammonium-loaded reversed phase HPLC column using a 5mM...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of liquid chromatography 1990-04, Vol.13 (7), p.1321-1338
Hauptverfasser: Treskes, M., Jong, J. De, Leeuwenkamp, O. R., Van Der Vijgh, W. J. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A sensitive method for the determination of the antitumor agent cisplatin has been developed consisting of solvent-generated anion exchange chromatography and on-line reductive electrochemical detection. CDDP was retained on a hexadecyl-trimethylammonium-loaded reversed phase HPLC column using a 5mM citrate-buffered eluent (pH 6.5). Exploiting adsorption of CDDP at a dropping mercury electrode and NH 4 +-enhanced catalytic proton reduction, a detection limit of 10 −8 M (3 ng/ml) has been achieved. Application of the developed method to the quantification of CDDP in plasma ultrafiltrate and urine is demonstrated and discussed.
ISSN:0148-3919
2331-0413
DOI:10.1080/01483919008049252