Ripple feedback for the resonant-filter unity-power-factor rectifier
An unusual bucklike unity-power-factor rectifier with a resonant load-balancing network permits current-limited operation down to zero output voltage in a single-stage topology. However, this rectifier has been found to be sensitive to AC-line voltage distortion and is potentially unstable with real...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 1992-07, Vol.7 (3), p.453-461 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An unusual bucklike unity-power-factor rectifier with a resonant load-balancing network permits current-limited operation down to zero output voltage in a single-stage topology. However, this rectifier has been found to be sensitive to AC-line voltage distortion and is potentially unstable with realistic values of AC-line impedances. A new ripple feedback is proposed that solves both problems. A large-signal time-varying analysis is given along with incremental, quasi-static, and low-frequency approximations. Experimental verification is provided by a 500 W 500 kHz rectifier operating from the 120 V, 60 Hz distribution system.< > |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/63.145132 |