Identification of the machine parameters in a vector-controlled induction motor drive

High dynamic performance of pulse-width-modulated (PWM) inverter-fed induction motor drives was achieved by using the method of field-oriented control. This method requires the actual value of the rotor time constant as essential system information, based on how the magnitude and the position of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industry applications 1991-11, Vol.27 (6), p.1111-1118
Hauptverfasser: Holtz, J., Thimm, T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:High dynamic performance of pulse-width-modulated (PWM) inverter-fed induction motor drives was achieved by using the method of field-oriented control. This method requires the actual value of the rotor time constant as essential system information, based on how the magnitude and the position of the rotor flux are calculated. An online identification technique for the rotor time constant and for other machine parameters is described. The identification is based on an evaluation of the stator current trajectory, which is the dynamic response of the induction motor to the PWM-switching sequence. An analytical machine model is operated in parallel to the actual machine, having the stator voltages and the mechanical speed of the induction motor as input signals. The coincidence of the two stator current trajectories of the model and the machine serves as an error indicator for the parameter identification scheme, permitting repetitive updates of the model parameters.< >
ISSN:0093-9994
1939-9367
DOI:10.1109/28.108462