High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage
In order to investigate the high altitude effect on dc corona inception voltage of power transmission lines, a mobile corona cage test system was constructed. The experiments were carried in Wuhan, Xining, Geermu, and Nachitai, respectively. Photons released as a result of corona discharge on the co...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power delivery 2013-07, Vol.28 (3), p.1971-1973 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1973 |
---|---|
container_issue | 3 |
container_start_page | 1971 |
container_title | IEEE transactions on power delivery |
container_volume | 28 |
creator | Xingming Bian Liming Wang Yunpeng Liu Yingjian Yang Zhicheng Guan |
description | In order to investigate the high altitude effect on dc corona inception voltage of power transmission lines, a mobile corona cage test system was constructed. The experiments were carried in Wuhan, Xining, Geermu, and Nachitai, respectively. Photons released as a result of corona discharge on the conductors were detected by the ultraviolet image detector. Both positive and negative corona inception voltages could be acquired by the "tangent method" based on the measured data. The approximate linear altitude correction formulas were suggested. |
doi_str_mv | 10.1109/TPWRD.2013.2258818 |
format | Article |
fullrecord | <record><control><sourceid>pascalfrancis_RIE</sourceid><recordid>TN_cdi_pascalfrancis_primary_27530218</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6515151</ieee_id><sourcerecordid>27530218</sourcerecordid><originalsourceid>FETCH-LOGICAL-c297t-5adf3114e5f276bda2c6602c90dcc1999fd08e265bddc75f0ecc7c7d62fa217b3</originalsourceid><addsrcrecordid>eNo9kE1PAjEQhhujiYj-Ab304nGx7dJte8QFhQQjMajHTekH1Cxb0pYY_727oGQOk8zM8yTzAnCL0QBjJB6Wi8-38YAgnA8IoZxjfgZ6WOQsGxLEz0EPcU4zLhi7BFcxfiGEhkigHthP3XoDR3Vyaa8NnFhrVIK-gaUPvpFw1iizS64dfPg6ybWJ0Fs4LuHCf5sAl0E2cetidAek0XuVfIjwUUajO03aGPjiV642_8aylVyDCyvraG7-eh-8P02W5TSbvz7PytE8U0SwlFGpbY7x0FBLWLHSkqiiQEQJpJXCQgirETekoCutFaMWGaWYYrogVhLMVnkfkKNXBR9jMLbaBbeV4afCqOqCqw7BVV1w1V9wLXR_hHYyKlnb9kXl4okkjOaIHO7ujnfOGHNaFxR3lf8CZ2Z4ig</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage</title><source>IEEE Xplore (Online service)</source><creator>Xingming Bian ; Liming Wang ; Yunpeng Liu ; Yingjian Yang ; Zhicheng Guan</creator><creatorcontrib>Xingming Bian ; Liming Wang ; Yunpeng Liu ; Yingjian Yang ; Zhicheng Guan</creatorcontrib><description>In order to investigate the high altitude effect on dc corona inception voltage of power transmission lines, a mobile corona cage test system was constructed. The experiments were carried in Wuhan, Xining, Geermu, and Nachitai, respectively. Photons released as a result of corona discharge on the conductors were detected by the ultraviolet image detector. Both positive and negative corona inception voltages could be acquired by the "tangent method" based on the measured data. The approximate linear altitude correction formulas were suggested.</description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/TPWRD.2013.2258818</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>Altitude ; Applied sciences ; Conductors ; Corona ; corona cage ; corona discharge ; corona inception voltage ; Detectors ; Discharges (electric) ; Electrical engineering. Electrical power engineering ; Electrical power engineering ; Exact sciences and technology ; Miscellaneous ; negative ; Photonics ; positive ; Power networks and lines ; Power transmission lines ; ultraviolet ; Voltage measurement</subject><ispartof>IEEE transactions on power delivery, 2013-07, Vol.28 (3), p.1971-1973</ispartof><rights>2014 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c297t-5adf3114e5f276bda2c6602c90dcc1999fd08e265bddc75f0ecc7c7d62fa217b3</citedby><cites>FETCH-LOGICAL-c297t-5adf3114e5f276bda2c6602c90dcc1999fd08e265bddc75f0ecc7c7d62fa217b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6515151$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6515151$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=27530218$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Xingming Bian</creatorcontrib><creatorcontrib>Liming Wang</creatorcontrib><creatorcontrib>Yunpeng Liu</creatorcontrib><creatorcontrib>Yingjian Yang</creatorcontrib><creatorcontrib>Zhicheng Guan</creatorcontrib><title>High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>In order to investigate the high altitude effect on dc corona inception voltage of power transmission lines, a mobile corona cage test system was constructed. The experiments were carried in Wuhan, Xining, Geermu, and Nachitai, respectively. Photons released as a result of corona discharge on the conductors were detected by the ultraviolet image detector. Both positive and negative corona inception voltages could be acquired by the "tangent method" based on the measured data. The approximate linear altitude correction formulas were suggested.</description><subject>Altitude</subject><subject>Applied sciences</subject><subject>Conductors</subject><subject>Corona</subject><subject>corona cage</subject><subject>corona discharge</subject><subject>corona inception voltage</subject><subject>Detectors</subject><subject>Discharges (electric)</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Electrical power engineering</subject><subject>Exact sciences and technology</subject><subject>Miscellaneous</subject><subject>negative</subject><subject>Photonics</subject><subject>positive</subject><subject>Power networks and lines</subject><subject>Power transmission lines</subject><subject>ultraviolet</subject><subject>Voltage measurement</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNo9kE1PAjEQhhujiYj-Ab304nGx7dJte8QFhQQjMajHTekH1Cxb0pYY_727oGQOk8zM8yTzAnCL0QBjJB6Wi8-38YAgnA8IoZxjfgZ6WOQsGxLEz0EPcU4zLhi7BFcxfiGEhkigHthP3XoDR3Vyaa8NnFhrVIK-gaUPvpFw1iizS64dfPg6ybWJ0Fs4LuHCf5sAl0E2cetidAek0XuVfIjwUUajO03aGPjiV642_8aylVyDCyvraG7-eh-8P02W5TSbvz7PytE8U0SwlFGpbY7x0FBLWLHSkqiiQEQJpJXCQgirETekoCutFaMWGaWYYrogVhLMVnkfkKNXBR9jMLbaBbeV4afCqOqCqw7BVV1w1V9wLXR_hHYyKlnb9kXl4okkjOaIHO7ujnfOGHNaFxR3lf8CZ2Z4ig</recordid><startdate>20130701</startdate><enddate>20130701</enddate><creator>Xingming Bian</creator><creator>Liming Wang</creator><creator>Yunpeng Liu</creator><creator>Yingjian Yang</creator><creator>Zhicheng Guan</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20130701</creationdate><title>High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage</title><author>Xingming Bian ; Liming Wang ; Yunpeng Liu ; Yingjian Yang ; Zhicheng Guan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c297t-5adf3114e5f276bda2c6602c90dcc1999fd08e265bddc75f0ecc7c7d62fa217b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Altitude</topic><topic>Applied sciences</topic><topic>Conductors</topic><topic>Corona</topic><topic>corona cage</topic><topic>corona discharge</topic><topic>corona inception voltage</topic><topic>Detectors</topic><topic>Discharges (electric)</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Electrical power engineering</topic><topic>Exact sciences and technology</topic><topic>Miscellaneous</topic><topic>negative</topic><topic>Photonics</topic><topic>positive</topic><topic>Power networks and lines</topic><topic>Power transmission lines</topic><topic>ultraviolet</topic><topic>Voltage measurement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xingming Bian</creatorcontrib><creatorcontrib>Liming Wang</creatorcontrib><creatorcontrib>Yunpeng Liu</creatorcontrib><creatorcontrib>Yingjian Yang</creatorcontrib><creatorcontrib>Zhicheng Guan</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Xplore (Online service)</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Xingming Bian</au><au>Liming Wang</au><au>Yunpeng Liu</au><au>Yingjian Yang</au><au>Zhicheng Guan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>2013-07-01</date><risdate>2013</risdate><volume>28</volume><issue>3</issue><spage>1971</spage><epage>1973</epage><pages>1971-1973</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>In order to investigate the high altitude effect on dc corona inception voltage of power transmission lines, a mobile corona cage test system was constructed. The experiments were carried in Wuhan, Xining, Geermu, and Nachitai, respectively. Photons released as a result of corona discharge on the conductors were detected by the ultraviolet image detector. Both positive and negative corona inception voltages could be acquired by the "tangent method" based on the measured data. The approximate linear altitude correction formulas were suggested.</abstract><cop>New York, NY</cop><pub>IEEE</pub><doi>10.1109/TPWRD.2013.2258818</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0885-8977 |
ispartof | IEEE transactions on power delivery, 2013-07, Vol.28 (3), p.1971-1973 |
issn | 0885-8977 1937-4208 |
language | eng |
recordid | cdi_pascalfrancis_primary_27530218 |
source | IEEE Xplore (Online service) |
subjects | Altitude Applied sciences Conductors Corona corona cage corona discharge corona inception voltage Detectors Discharges (electric) Electrical engineering. Electrical power engineering Electrical power engineering Exact sciences and technology Miscellaneous negative Photonics positive Power networks and lines Power transmission lines ultraviolet Voltage measurement |
title | High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T09%3A35%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pascalfrancis_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20Altitude%20Effect%20on%20Corona%20Inception%20Voltages%20of%20DC%20Power%20Transmission%20Conductors%20Based%20on%20the%20Mobile%20Corona%20Cage&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Xingming%20Bian&rft.date=2013-07-01&rft.volume=28&rft.issue=3&rft.spage=1971&rft.epage=1973&rft.pages=1971-1973&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/TPWRD.2013.2258818&rft_dat=%3Cpascalfrancis_RIE%3E27530218%3C/pascalfrancis_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=6515151&rfr_iscdi=true |