Analytical Model of Permeance Variation Losses in Permanent Magnets of the Multipole Synchronous Machine

Permeance variation in the air gap of the permanent-magnet synchronous machine induces eddy-current losses in its permanent magnets even in the absence of stator currents. This paper proposes a new analytical approach to analyze these losses using the permeance-variation vector function introduced f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 2013-02, Vol.49 (2), p.921-928
Hauptverfasser: Gotovac, Gorazd, Lampic, Gorazd, Miljavec, Damijan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Permeance variation in the air gap of the permanent-magnet synchronous machine induces eddy-current losses in its permanent magnets even in the absence of stator currents. This paper proposes a new analytical approach to analyze these losses using the permeance-variation vector function introduced for the air-gap magnetic-flux density distribution to take into account the stator teeth. The Laplace equation is employed to derive the radial dependency of the stator slotting effect on the magnetic-flux density distribution. The induced eddy currents are further calculated by using Faraday's law. The analytical results are compared with the numerical ones based on the finite-element analysis. The paper offers a faster alternative to the numerically intensive calculations of eddy-current losses, and the method is especially useful in initial design optimization of the electric machine.
ISSN:0018-9464
1941-0069
DOI:10.1109/TMAG.2012.2212715