Sensitivity analysis of fuel pin failure performance under slow-ramp type transient overpower condition by using a fuel performance analysis code FEMAXI-FBR
The FEMAXI-FBR is a fuel performance analysis code and has been developed as one module of core disruptive evaluation system, the ASTERIA-FBR. The FEMAXI-FBR has reproduced the failure pin behavior during slow transient overpower. The axial location of pin failure affects the power and reactivity be...
Gespeichert in:
Veröffentlicht in: | Journal of nuclear science and technology 2012-10, Vol.49 (10), p.975-987 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The FEMAXI-FBR is a fuel performance analysis code and has been developed as one module of core disruptive evaluation system, the ASTERIA-FBR. The FEMAXI-FBR has reproduced the failure pin behavior during slow transient overpower. The axial location of pin failure affects the power and reactivity behavior during core disruptive accident, and failure model of which pin failure occurs at upper part of pin is used by reflecting the results of the CABRI-2 test. By using the FEMAXI-FBR, sensitivity analysis of uncertainty of design parameters such as irradiation conditions and fuel fabrication tolerances was performed to clarify the effect on axial location of pin failure during slow transient overpower. The sensitivity analysis showed that the uncertainty of design parameters does not affect the failure location. It suggests that the failure model with which locations of failure occur at upper part of pin can be adopted for core disruptive calculation by taking into consideration of design uncertainties. |
---|---|
ISSN: | 0022-3131 1881-1248 |