Time quantity one-cycle control for power-factor correctors
A time quantity one-cycle control method is proposed in this paper for unity power-factor AC-DC power converters. Power converters controlled by this method operate at constant switching frequency, require no current sensing, have a simple control circuit and exhibit resistive input impedance at the...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 1997-03, Vol.12 (2), p.369-375 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A time quantity one-cycle control method is proposed in this paper for unity power-factor AC-DC power converters. Power converters controlled by this method operate at constant switching frequency, require no current sensing, have a simple control circuit and exhibit resistive input impedance at the AC side. A feedback loop design method is provided to minimize the current distortion when the output voltage ripple is not negligible. Experimental results confirmed the theoretical prediction. |
---|---|
ISSN: | 0885-8993 1941-0107 |