Study on Field Measurement and Ground Vibration for Superconducting Solenoid of New g-2 Experiment at J-PARC
Basic R&Ds of a superconducting solenoid for a new g-2 experiment at J-PARC are on going. High uniformity of magnetic field below 0.1 ppm is required for the g-2 experiment within a storage region of 33.3±5 cm in radius and ±10 cm in height. Two R&Ds have been started to develop the magnet w...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2011-06, Vol.21 (3), p.1748-1751 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Basic R&Ds of a superconducting solenoid for a new g-2 experiment at J-PARC are on going. High uniformity of magnetic field below 0.1 ppm is required for the g-2 experiment within a storage region of 33.3±5 cm in radius and ±10 cm in height. Two R&Ds have been started to develop the magnet with such high uniformity; a development of a precise field monitoring system and a study of seismic ground vibration. The prototype monitoring system using continuous wave type NMR probe for horizontal MRI solenoid has been built and tested. Cross-check between NMR and Hall probe has been also carried out. The seismic ground vibration has been measured at Materials and Life science Facility, MLF, in J-PARC. Based on the measured results, the spectrum analysis of the iron yoke has been performed using ANSYS. |
---|---|
ISSN: | 1051-8223 1558-2515 |