Wideband wattmeter based on RMS voltage measurements
A wideband wattmeter for measuring active power over a frequency range of dc to 500 kHz is described. The wattmeter is based on the three-voltmeter method in which three rms voltage measurements are used to calculate power. The wattmeter active power uncertainty is estimated to be within 0.03% from...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on instrumentation and measurement 1997-08, Vol.46 (4), p.781-783 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A wideband wattmeter for measuring active power over a frequency range of dc to 500 kHz is described. The wattmeter is based on the three-voltmeter method in which three rms voltage measurements are used to calculate power. The wattmeter active power uncertainty is estimated to be within 0.03% from dc to 20 kHz and within 1.5% to 500 kHz. |
---|---|
ISSN: | 0018-9456 1557-9662 |
DOI: | 10.1109/19.650772 |