AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples

We present an overview of accelerator mass spectrometry (AMS) radiocarbon sample preparation and measurements, describing the technical upgrades that now allow us to routinely obtain 0.2–0.3% precision for 1-mg carbon samples. A precision of ∼1% on samples with 100 μg of carbon can also be achieved....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiocarbon 2007, Vol.49 (2), p.255-269
Hauptverfasser: Santos, G M, Moore, R B, Southon, J R, Griffin, S, Hinger, E, Zhang, D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 269
container_issue 2
container_start_page 255
container_title Radiocarbon
container_volume 49
creator Santos, G M
Moore, R B
Southon, J R
Griffin, S
Hinger, E
Zhang, D
description We present an overview of accelerator mass spectrometry (AMS) radiocarbon sample preparation and measurements, describing the technical upgrades that now allow us to routinely obtain 0.2–0.3% precision for 1-mg carbon samples. A precision of ∼1% on samples with 100 μg of carbon can also be achieved. We have also developed graphitization techniques and AMS procedures for ultra-small samples (down to 0.002 mg of carbon). Detailed time series are presented for large and small aliquots of standards such as NIST OX-I and OX-II; FIRI-C and -D; IAEA-C6, -C7 and -C8; and 14C-free samples.
doi_str_mv 10.1017/S0033822200042181
format Article
fullrecord <record><control><sourceid>cambridge_pasca</sourceid><recordid>TN_cdi_pascalfrancis_primary_20358344</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cupid>10_1017_S0033822200042181</cupid><sourcerecordid>10_1017_S0033822200042181</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1831-ef041466eabd2e2e1044319f1737c061379a830acc7a3397437bc2545cf9b95b3</originalsourceid><addsrcrecordid>eNplkD1PwzAURS0EEqXwA9i8MIb6-dlxwlZFtFQUURE6Ry-uA6nyJScd-u9J1W5MdzhXR1eXsUcQzyDAzFIhECMppRBCSYjgik0gVjrQRutrNjnh4MRv2V3f74WQEEZmwtz8I-WgEp5S3VWOb7zryNNQtg2ngQ-_jr8nyViabZMVX5Atq3I4vvB0oOHQ8y_XtX7g1Oz4xvmi9TU11vG24GlNVXWx9vfspqCqdw-XnLLt4vU7eQvWn8tVMl8HFiKEwBVCgQpDR_lOOulAKIUQF2DQWBECmpgiFGStIcTYKDS5lVppW8R5rHOcsqezt6PeUlX4cU3ZZ50va_LHTArUEY7OKcNzz1Kd-3L347J9e_DNuC0DkZ0ezf49in_W6WV3</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples</title><source>Cambridge Journals Online</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Free Full-Text Journals in Chemistry</source><creator>Santos, G M ; Moore, R B ; Southon, J R ; Griffin, S ; Hinger, E ; Zhang, D</creator><creatorcontrib>Santos, G M ; Moore, R B ; Southon, J R ; Griffin, S ; Hinger, E ; Zhang, D</creatorcontrib><description>We present an overview of accelerator mass spectrometry (AMS) radiocarbon sample preparation and measurements, describing the technical upgrades that now allow us to routinely obtain 0.2–0.3% precision for 1-mg carbon samples. A precision of ∼1% on samples with 100 μg of carbon can also be achieved. We have also developed graphitization techniques and AMS procedures for ultra-small samples (down to 0.002 mg of carbon). Detailed time series are presented for large and small aliquots of standards such as NIST OX-I and OX-II; FIRI-C and -D; IAEA-C6, -C7 and -C8; and 14C-free samples.</description><identifier>ISSN: 0033-8222</identifier><identifier>EISSN: 1945-5755</identifier><identifier>DOI: 10.1017/S0033822200042181</identifier><language>eng</language><publisher>New York, US: Cambridge University Press</publisher><subject>Art and archaeology ; Dating ; Generalities ; Laboratory technics ; Methodology ; Methods ; Research principies ; Sample Preparation</subject><ispartof>Radiocarbon, 2007, Vol.49 (2), p.255-269</ispartof><rights>Copyright © 2007 by the Arizona Board of Regents on behalf of the University of Arizona</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.cambridge.org/core/product/identifier/S0033822200042181/type/journal_article$$EHTML$$P50$$Gcambridge$$H</linktohtml><link.rule.ids>164,309,310,314,776,780,785,786,4010,4036,4037,23909,23910,25118,27900,27901,27902,55603</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=20358344$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Santos, G M</creatorcontrib><creatorcontrib>Moore, R B</creatorcontrib><creatorcontrib>Southon, J R</creatorcontrib><creatorcontrib>Griffin, S</creatorcontrib><creatorcontrib>Hinger, E</creatorcontrib><creatorcontrib>Zhang, D</creatorcontrib><title>AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples</title><title>Radiocarbon</title><addtitle>Radiocarbon</addtitle><description>We present an overview of accelerator mass spectrometry (AMS) radiocarbon sample preparation and measurements, describing the technical upgrades that now allow us to routinely obtain 0.2–0.3% precision for 1-mg carbon samples. A precision of ∼1% on samples with 100 μg of carbon can also be achieved. We have also developed graphitization techniques and AMS procedures for ultra-small samples (down to 0.002 mg of carbon). Detailed time series are presented for large and small aliquots of standards such as NIST OX-I and OX-II; FIRI-C and -D; IAEA-C6, -C7 and -C8; and 14C-free samples.</description><subject>Art and archaeology</subject><subject>Dating</subject><subject>Generalities</subject><subject>Laboratory technics</subject><subject>Methodology</subject><subject>Methods</subject><subject>Research principies</subject><subject>Sample Preparation</subject><issn>0033-8222</issn><issn>1945-5755</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNplkD1PwzAURS0EEqXwA9i8MIb6-dlxwlZFtFQUURE6Ry-uA6nyJScd-u9J1W5MdzhXR1eXsUcQzyDAzFIhECMppRBCSYjgik0gVjrQRutrNjnh4MRv2V3f74WQEEZmwtz8I-WgEp5S3VWOb7zryNNQtg2ngQ-_jr8nyViabZMVX5Atq3I4vvB0oOHQ8y_XtX7g1Oz4xvmi9TU11vG24GlNVXWx9vfspqCqdw-XnLLt4vU7eQvWn8tVMl8HFiKEwBVCgQpDR_lOOulAKIUQF2DQWBECmpgiFGStIcTYKDS5lVppW8R5rHOcsqezt6PeUlX4cU3ZZ50va_LHTArUEY7OKcNzz1Kd-3L347J9e_DNuC0DkZ0ezf49in_W6WV3</recordid><startdate>2007</startdate><enddate>2007</enddate><creator>Santos, G M</creator><creator>Moore, R B</creator><creator>Southon, J R</creator><creator>Griffin, S</creator><creator>Hinger, E</creator><creator>Zhang, D</creator><general>Cambridge University Press</general><general>University of Arizona</general><scope>IQODW</scope></search><sort><creationdate>2007</creationdate><title>AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples</title><author>Santos, G M ; Moore, R B ; Southon, J R ; Griffin, S ; Hinger, E ; Zhang, D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1831-ef041466eabd2e2e1044319f1737c061379a830acc7a3397437bc2545cf9b95b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Art and archaeology</topic><topic>Dating</topic><topic>Generalities</topic><topic>Laboratory technics</topic><topic>Methodology</topic><topic>Methods</topic><topic>Research principies</topic><topic>Sample Preparation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Santos, G M</creatorcontrib><creatorcontrib>Moore, R B</creatorcontrib><creatorcontrib>Southon, J R</creatorcontrib><creatorcontrib>Griffin, S</creatorcontrib><creatorcontrib>Hinger, E</creatorcontrib><creatorcontrib>Zhang, D</creatorcontrib><collection>Pascal-Francis</collection><jtitle>Radiocarbon</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Santos, G M</au><au>Moore, R B</au><au>Southon, J R</au><au>Griffin, S</au><au>Hinger, E</au><au>Zhang, D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples</atitle><jtitle>Radiocarbon</jtitle><addtitle>Radiocarbon</addtitle><date>2007</date><risdate>2007</risdate><volume>49</volume><issue>2</issue><spage>255</spage><epage>269</epage><pages>255-269</pages><issn>0033-8222</issn><eissn>1945-5755</eissn><abstract>We present an overview of accelerator mass spectrometry (AMS) radiocarbon sample preparation and measurements, describing the technical upgrades that now allow us to routinely obtain 0.2–0.3% precision for 1-mg carbon samples. A precision of ∼1% on samples with 100 μg of carbon can also be achieved. We have also developed graphitization techniques and AMS procedures for ultra-small samples (down to 0.002 mg of carbon). Detailed time series are presented for large and small aliquots of standards such as NIST OX-I and OX-II; FIRI-C and -D; IAEA-C6, -C7 and -C8; and 14C-free samples.</abstract><cop>New York, US</cop><pub>Cambridge University Press</pub><doi>10.1017/S0033822200042181</doi><tpages>15</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0033-8222
ispartof Radiocarbon, 2007, Vol.49 (2), p.255-269
issn 0033-8222
1945-5755
language eng
recordid cdi_pascalfrancis_primary_20358344
source Cambridge Journals Online; EZB-FREE-00999 freely available EZB journals; Free Full-Text Journals in Chemistry
subjects Art and archaeology
Dating
Generalities
Laboratory technics
Methodology
Methods
Research principies
Sample Preparation
title AMS 14C Sample Preparation at the KCCAMS/UCI Facility: Status Report and Performance of Small Samples
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T23%3A29%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-cambridge_pasca&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=AMS%2014C%20Sample%20Preparation%20at%20the%20KCCAMS/UCI%20Facility:%20Status%20Report%20and%20Performance%20of%20Small%20Samples&rft.jtitle=Radiocarbon&rft.au=Santos,%20G%20M&rft.date=2007&rft.volume=49&rft.issue=2&rft.spage=255&rft.epage=269&rft.pages=255-269&rft.issn=0033-8222&rft.eissn=1945-5755&rft_id=info:doi/10.1017/S0033822200042181&rft_dat=%3Ccambridge_pasca%3E10_1017_S0033822200042181%3C/cambridge_pasca%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_cupid=10_1017_S0033822200042181&rfr_iscdi=true