NARX models of an industrial power plant gas turbine

This brief reports the experience with the identification of a nonlinear autoregressive with exogenous inputs (NARX) model for the PGT10B1 power plant gas turbine manufactured by General Electric-Nuovo Pignone. Two operating conditions of the turbine are considered: isolated mode and nonisolated mod...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on control systems technology 2005-07, Vol.13 (4), p.599-604
Hauptverfasser: Basso, M., Giarre, L., Groppi, S., Zappa, G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This brief reports the experience with the identification of a nonlinear autoregressive with exogenous inputs (NARX) model for the PGT10B1 power plant gas turbine manufactured by General Electric-Nuovo Pignone. Two operating conditions of the turbine are considered: isolated mode and nonisolated mode. The NARX model parameters are estimated iteratively with a Gram-Schmidt procedure, exploiting both forward and stepwise regression. Many indexes have been evaluated and compared in order to perform subset selection in the functional basis set and determine the structure of the nonlinear model. Various input signals (from narrow to broadband) for identification and validation have been considered.
ISSN:1063-6536
1558-0865
DOI:10.1109/TCST.2004.843129