Measurement of wall voltage in barrier discharges using an electro-optic nonlinear crystal
The wall voltage in a barrier discharge has been directly measured using an electro-optic crystal, KDP. One of the barriers is made up of a plate of KDP. A wall voltage due to charges accumulated on KDP surface is measured at various discharge conditions from the change of polarization of a laser tr...
Gespeichert in:
Veröffentlicht in: | Journal of physics. D, Applied physics Applied physics, 2003-12, Vol.36 (23), p.2887-2890 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The wall voltage in a barrier discharge has been directly measured using an electro-optic crystal, KDP. One of the barriers is made up of a plate of KDP. A wall voltage due to charges accumulated on KDP surface is measured at various discharge conditions from the change of polarization of a laser transmitting through KDP. The value of the wall voltage at applied voltage of 1 kV and Ar gas pressure of 3 Torr is about 120 V. This indicates that the accumulated charge is about 1.1 nC. |
---|---|