The Effect of Heliox-Driven Bronchodilator Aerosol Therapy on Pulmonary Function Tests in Patients with Asthma

To compare the effects of heliox-driven (He 80:O2 20) to air-driven (N 79:O2 21) β2-agonist aerosol therapy on pulmonary function tests (PFTs) in patients with asthma, a prospective randomized crossover study was undertaken in the asthma clinic of the university-affiliated county hospital in Houston...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of asthma 2002-01, Vol.39 (7), p.659-665
Hauptverfasser: Bag, Remzi, Bandi, Venkata, Fromm, Robert E., Guntupalli, Kalpalatha K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To compare the effects of heliox-driven (He 80:O2 20) to air-driven (N 79:O2 21) β2-agonist aerosol therapy on pulmonary function tests (PFTs) in patients with asthma, a prospective randomized crossover study was undertaken in the asthma clinic of the university-affiliated county hospital in Houston, TX. Thirty-one patients (22 female, age range 18-44) with clinically stable asthma consented. All patients were studied on two different days with both heliox and air as driving gas, therefore serving as their own controls. The PFTs including forced expiratory volume in 1 sec (FEV1), forced vital capacity (FVC), maximal mid-expiratory flow rate (FEF25-75), and maximal expiratory flow rate (FEFmax) were obtained while breathing ambient air at baseline and 30 min after the bronchodilator treatment. Albuterol sulfate 2.5 mg was nebulized with either heliox or compressed air at 8 L min for 8 min. When heliox was used as driving agent, additional heliox was delivered via a closed system and no entrainment of external air was allowed. Primary outcome measure was absolute change in FEV1 (ΔFEV1). There were no statistically significant differences in baseline PFTs on the two days of the study. All patients had good bronchodilator response (≥12% improvement in FEV1) with either driving gas. The ΔFEV1 after heliox-driven bronchodilator (HDBD) and air-driven bronchodilator (ADBD) were 0.68±0.38 L sec (CI: 0.54-0.82) vs. 0.51±0.26 L sec (CI: 0.42-0.60), respectively (p=0.004). The ΔFEV1 with HDBD was 49±90% (range −36% to 433%) more than ADBD. A subgroup analysis showed this was largely due to better response rates in patients with moderate to severe obstruction. There was more improvement in both FVC and FEFmax with HDBD than ADBD (p
ISSN:0277-0903
1532-4303
DOI:10.1081/JAS-120014931