A VXIbus based trigger for the CLAS detector at CEBAF
A VXIbus based first level triggering system for the CLAS detector at CEBAF has been designed and prototyped. It uses pipelining and a triple memory lookup to produce a dead-timeless trigger decision with an average latency of 110 nS and a jitter of 20 nS. The VXIbus Extended Start/Stop triggering p...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nuclear science 1992-04, Vol.39 (2) |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 2 |
container_start_page | |
container_title | IEEE transactions on nuclear science |
container_volume | 39 |
creator | D.C. Doughty, Jr J. Englert R. Hale S. Lemon P. Leung C. Cuevas D. Joyce |
description | A VXIbus based first level triggering system for the CLAS detector at CEBAF has been designed and prototyped. It uses pipelining and a triple memory lookup to produce a dead-timeless trigger decision with an average latency of 110 nS and a jitter of 20 nS. The VXIbus Extended Start/Stop triggering protocols allow sub-nanosecond time synchronization. |
doi_str_mv | 10.1109/23.277490 |
format | Article |
fullrecord | <record><control><sourceid>osti</sourceid><recordid>TN_cdi_osti_scitechconnect_840642</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>840642</sourcerecordid><originalsourceid>FETCH-osti_scitechconnect_8406423</originalsourceid><addsrcrecordid>eNqNi0sKwjAURR-iYP0M3MFzAa1Jm5hkWEuLgjNFnJV-0o9IC03cvxm4AEeXczgXYEdJQClRhzAKQiGYIjPwKOfSp1zIOXiEUOkrptQSVsa8HDJOuAc8xsfzUn4MloXRNdqpb1s9YTNOaDuNyTW-Ya2trqwzhcUkPcXZBhZN8TZ6-9s17LP0npz90dg-N1Xv-q4ah8HdcsnIkYXRP80XTGE3FQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A VXIbus based trigger for the CLAS detector at CEBAF</title><source>IEEE Electronic Library (IEL)</source><creator>D.C. Doughty, Jr ; J. Englert ; R. Hale ; S. Lemon ; P. Leung ; C. Cuevas ; D. Joyce</creator><creatorcontrib>D.C. Doughty, Jr ; J. Englert ; R. Hale ; S. Lemon ; P. Leung ; C. Cuevas ; D. Joyce ; Thomas Jefferson National Accelerator Facility, Newport News, VA (US)</creatorcontrib><description>A VXIbus based first level triggering system for the CLAS detector at CEBAF has been designed and prototyped. It uses pipelining and a triple memory lookup to produce a dead-timeless trigger decision with an average latency of 110 nS and a jitter of 20 nS. The VXIbus Extended Start/Stop triggering protocols allow sub-nanosecond time synchronization.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/23.277490</identifier><language>eng</language><publisher>United States</publisher><subject>CEBAF ACCELERATOR ; COMPUTERIZED CONTROL SYSTEMS ; DRIFT CHAMBERS ; INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; PARTICLE ACCELERATORS ; SYNCHRONIZATION</subject><ispartof>IEEE transactions on nuclear science, 1992-04, Vol.39 (2)</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27923,27924</link.rule.ids><backlink>$$Uhttps://www.osti.gov/servlets/purl/840642$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>D.C. Doughty, Jr</creatorcontrib><creatorcontrib>J. Englert</creatorcontrib><creatorcontrib>R. Hale</creatorcontrib><creatorcontrib>S. Lemon</creatorcontrib><creatorcontrib>P. Leung</creatorcontrib><creatorcontrib>C. Cuevas</creatorcontrib><creatorcontrib>D. Joyce</creatorcontrib><creatorcontrib>Thomas Jefferson National Accelerator Facility, Newport News, VA (US)</creatorcontrib><title>A VXIbus based trigger for the CLAS detector at CEBAF</title><title>IEEE transactions on nuclear science</title><description>A VXIbus based first level triggering system for the CLAS detector at CEBAF has been designed and prototyped. It uses pipelining and a triple memory lookup to produce a dead-timeless trigger decision with an average latency of 110 nS and a jitter of 20 nS. The VXIbus Extended Start/Stop triggering protocols allow sub-nanosecond time synchronization.</description><subject>CEBAF ACCELERATOR</subject><subject>COMPUTERIZED CONTROL SYSTEMS</subject><subject>DRIFT CHAMBERS</subject><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>PARTICLE ACCELERATORS</subject><subject>SYNCHRONIZATION</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><recordid>eNqNi0sKwjAURR-iYP0M3MFzAa1Jm5hkWEuLgjNFnJV-0o9IC03cvxm4AEeXczgXYEdJQClRhzAKQiGYIjPwKOfSp1zIOXiEUOkrptQSVsa8HDJOuAc8xsfzUn4MloXRNdqpb1s9YTNOaDuNyTW-Ya2trqwzhcUkPcXZBhZN8TZ6-9s17LP0npz90dg-N1Xv-q4ah8HdcsnIkYXRP80XTGE3FQ</recordid><startdate>19920401</startdate><enddate>19920401</enddate><creator>D.C. Doughty, Jr</creator><creator>J. Englert</creator><creator>R. Hale</creator><creator>S. Lemon</creator><creator>P. Leung</creator><creator>C. Cuevas</creator><creator>D. Joyce</creator><scope>OIOZB</scope><scope>OTOTI</scope></search><sort><creationdate>19920401</creationdate><title>A VXIbus based trigger for the CLAS detector at CEBAF</title><author>D.C. Doughty, Jr ; J. Englert ; R. Hale ; S. Lemon ; P. Leung ; C. Cuevas ; D. Joyce</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-osti_scitechconnect_8406423</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>CEBAF ACCELERATOR</topic><topic>COMPUTERIZED CONTROL SYSTEMS</topic><topic>DRIFT CHAMBERS</topic><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>PARTICLE ACCELERATORS</topic><topic>SYNCHRONIZATION</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>D.C. Doughty, Jr</creatorcontrib><creatorcontrib>J. Englert</creatorcontrib><creatorcontrib>R. Hale</creatorcontrib><creatorcontrib>S. Lemon</creatorcontrib><creatorcontrib>P. Leung</creatorcontrib><creatorcontrib>C. Cuevas</creatorcontrib><creatorcontrib>D. Joyce</creatorcontrib><creatorcontrib>Thomas Jefferson National Accelerator Facility, Newport News, VA (US)</creatorcontrib><collection>OSTI.GOV - Hybrid</collection><collection>OSTI.GOV</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>D.C. Doughty, Jr</au><au>J. Englert</au><au>R. Hale</au><au>S. Lemon</au><au>P. Leung</au><au>C. Cuevas</au><au>D. Joyce</au><aucorp>Thomas Jefferson National Accelerator Facility, Newport News, VA (US)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A VXIbus based trigger for the CLAS detector at CEBAF</atitle><jtitle>IEEE transactions on nuclear science</jtitle><date>1992-04-01</date><risdate>1992</risdate><volume>39</volume><issue>2</issue><issn>0018-9499</issn><eissn>1558-1578</eissn><abstract>A VXIbus based first level triggering system for the CLAS detector at CEBAF has been designed and prototyped. It uses pipelining and a triple memory lookup to produce a dead-timeless trigger decision with an average latency of 110 nS and a jitter of 20 nS. The VXIbus Extended Start/Stop triggering protocols allow sub-nanosecond time synchronization.</abstract><cop>United States</cop><doi>10.1109/23.277490</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0018-9499 |
ispartof | IEEE transactions on nuclear science, 1992-04, Vol.39 (2) |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_osti_scitechconnect_840642 |
source | IEEE Electronic Library (IEL) |
subjects | CEBAF ACCELERATOR COMPUTERIZED CONTROL SYSTEMS DRIFT CHAMBERS INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY PARTICLE ACCELERATORS SYNCHRONIZATION |
title | A VXIbus based trigger for the CLAS detector at CEBAF |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T16%3A59%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-osti&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20VXIbus%20based%20trigger%20for%20the%20CLAS%20detector%20at%20CEBAF&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=D.C.%20Doughty,%20Jr&rft.aucorp=Thomas%20Jefferson%20National%20Accelerator%20Facility,%20Newport%20News,%20VA%20(US)&rft.date=1992-04-01&rft.volume=39&rft.issue=2&rft.issn=0018-9499&rft.eissn=1558-1578&rft_id=info:doi/10.1109/23.277490&rft_dat=%3Costi%3E840642%3C/osti%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |