A VXIbus based trigger for the CLAS detector at CEBAF

A VXIbus based first level triggering system for the CLAS detector at CEBAF has been designed and prototyped. It uses pipelining and a triple memory lookup to produce a dead-timeless trigger decision with an average latency of 110 nS and a jitter of 20 nS. The VXIbus Extended Start/Stop triggering p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 1992-04, Vol.39 (2)
Hauptverfasser: D.C. Doughty, Jr, J. Englert, R. Hale, S. Lemon, P. Leung, C. Cuevas, D. Joyce
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A VXIbus based first level triggering system for the CLAS detector at CEBAF has been designed and prototyped. It uses pipelining and a triple memory lookup to produce a dead-timeless trigger decision with an average latency of 110 nS and a jitter of 20 nS. The VXIbus Extended Start/Stop triggering protocols allow sub-nanosecond time synchronization.
ISSN:0018-9499
1558-1578
DOI:10.1109/23.277490