Shot‐to‐shot comparison of the first Li‐beam‐driven hohlraum experiments

Shot‐to‐shot comparison of the first Li‐beam hohlraum experiments on PBFA II provides an opportunity to measure and determine the factor that affect the on‐axis reproducibility of the Li‐ion beam. Both inner‐shell and thermal x‐ray emission are used to estimate the relative beam power on target from...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of Scientific Instruments 1995-01, Vol.66 (1), p.740-742
Hauptverfasser: Derzon, M. S., Rochau, G. E., Chandler, G. A., Moats, A. R., Leeper, R. J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Shot‐to‐shot comparison of the first Li‐beam hohlraum experiments on PBFA II provides an opportunity to measure and determine the factor that affect the on‐axis reproducibility of the Li‐ion beam. Both inner‐shell and thermal x‐ray emission are used to estimate the relative beam power on target from shot to shot. The M‐ and L‐shell Au x‐ray yield measurements were made with an array of 11 filtered p‐i‐n detectors, and the thermal emission measurements were made with an array of three filtered bolometers. The analysis shows that the beam intensity on target varied by more than a factor of 10 during the shot series. By correlating the results of the beam on target with other diagnostics and events, we have identified some potential causes for these variations.
ISSN:0034-6748
1089-7623