Critical currents of Nb/sub 3/Sn wires for the US-DPC coil
The critical current of titanium-alloyed internal-tin, jelly-roll Nb/sub 3/Sn wire for use in the US Demonstration Poloidal Coil (US-DPC) was evaluated. It was confirmed from 14 randomly-selected samples that the critical-current values were uniform and consistent: the noncopper critical-current den...
Gespeichert in:
Veröffentlicht in: | IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States) 1991-03, Vol.27 (2), p.1767-1770 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The critical current of titanium-alloyed internal-tin, jelly-roll Nb/sub 3/Sn wire for use in the US Demonstration Poloidal Coil (US-DPC) was evaluated. It was confirmed from 14 randomly-selected samples that the critical-current values were uniform and consistent: the noncopper critical-current density was approximately 700 A/mm/sup 2/ at 10 T and 4.2 K, in agreement with expectations. A 27-strand cable-in-conduit conductor (CICC) using the low-thermal-coefficient-of-expansion superalloy Incoloy 905 yielded a critical current 5-7% below the average value of the single-strand data. |
---|---|
ISSN: | 0018-9464 1941-0069 |
DOI: | 10.1109/20.133533 |