Critical currents of Nb/sub 3/Sn wires for the US-DPC coil

The critical current of titanium-alloyed internal-tin, jelly-roll Nb/sub 3/Sn wire for use in the US Demonstration Poloidal Coil (US-DPC) was evaluated. It was confirmed from 14 randomly-selected samples that the critical-current values were uniform and consistent: the noncopper critical-current den...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States) 1991-03, Vol.27 (2), p.1767-1770
Hauptverfasser: Takayasu, M., Gung, C.Y., Steeves, M.M., Hoenig, M.O., Hale, J.R., Smathers, D.B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The critical current of titanium-alloyed internal-tin, jelly-roll Nb/sub 3/Sn wire for use in the US Demonstration Poloidal Coil (US-DPC) was evaluated. It was confirmed from 14 randomly-selected samples that the critical-current values were uniform and consistent: the noncopper critical-current density was approximately 700 A/mm/sup 2/ at 10 T and 4.2 K, in agreement with expectations. A 27-strand cable-in-conduit conductor (CICC) using the low-thermal-coefficient-of-expansion superalloy Incoloy 905 yielded a critical current 5-7% below the average value of the single-strand data.
ISSN:0018-9464
1941-0069