Effect of exercise level on the ability of thallium-201 tomographic imaging in detecting coronary artery disease: Analysis of 461 patients
This study examined the effect of the level of exercise on the ability of thallium-201 imaging with single photon emission computed tomography (SPECT) to detect coronary artery disease. Patients in group 1 (n = 164) achieved adequate exercise end points, defined as positive exercise electrocardiogra...
Gespeichert in:
Veröffentlicht in: | Journal of the American College of Cardiology 1989-11, Vol.14 (6), p.1477-1486 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study examined the effect of the level of exercise on the ability of thallium-201 imaging with single photon emission computed tomography (SPECT) to detect coronary artery disease. Patients in group 1 (n = 164) achieved adequate exercise end points, defined as positive exercise electrocardiograms or ≥85% of maximal predicted heart rate. Patients in group 2 (n = 108) had submaximal exercise.
The SPECT thallium-201 images showed perfusion defects in 74%, 88% and 98%, respectively, of patients with one, two and three vessel coronary artery disease in group 1, compared with 52%, 84% and 79%, respectively, of such patients in group 2 (p < 0.05).
Perfusion defects showed partial or complete redistribution consistent with ischemia in 56%, 80% and 88%, respectively, of patients with one, two and three vessel coronary artery disease in group 1 compared with 35%, 58% and 56%, respectively, of such patients in group 2 (p = 0.08, < 0.03 and < 0.001, respectively).
Of 58 patients with normal coronary angiograms or |
---|---|
ISSN: | 0735-1097 1558-3597 |