Methods and preliminary measurement results of liquid Li wettability

A test of lithium wettability was performed in high vacuum (< 3 × 10(-4) Pa). High magnification images of Li droplets on stainless steel substrates were produced and processed using the MATLAB(®) program to obtain clear image edge points. In contrast to the more standard "θ/2" or polyn...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2014-02, Vol.85 (2), p.023506-023506
Hauptverfasser: Zuo, G Z, Hu, J S, Ren, J, Sun, Z, Yang, Q X, Li, J G, Zakharov, L E, Mansfield, D K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A test of lithium wettability was performed in high vacuum (< 3 × 10(-4) Pa). High magnification images of Li droplets on stainless steel substrates were produced and processed using the MATLAB(®) program to obtain clear image edge points. In contrast to the more standard "θ/2" or polynomial fitting methods, ellipse fitting of the complete Li droplet shape resulted in reliable contact angle measurements over a wide range of contact angles. Using the ellipse fitting method, it was observed that the contact angle of a liquid Li droplet on a stainless steel substrate gradually decreased with increasing substrate temperature. The critical wetting temperature of liquid Li on stainless steel was observed to be about 290 °C.
ISSN:0034-6748
1089-7623
DOI:10.1063/1.4865118