Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

Purpose Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patie...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiovascular and interventional radiology 2013-04, Vol.36 (2), p.484-491
Hauptverfasser: Power, Sarah, Kavanagh, Liam N., Shields, Mary C., Given, Mark F., Keeling, Aoife N., McGrath, Frank P., Lee, Michael J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. Methods All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. Results A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period. Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 ( n  = 2), and the average tube dwell time was 125 days. Conclusions Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.
ISSN:0174-1551
1432-086X
DOI:10.1007/s00270-012-0456-3