Measurements of electron density and temperature in the H-1 heliac plasma by helium line intensity ratios

Electron density and temperature distributions in the H-1 heliac plasma are measured using the helium line intensity ratio technique based on a collisional-radiative model. An inversion approach with minimum Fisher regularization is developed to reconstruct the ratios of the local emission radiances...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2012-03, Vol.83 (3), p.033102-033102-7
Hauptverfasser: Ma, Shuiliang, Howard, John, Blackwell, Boyd D., Thapar, Nandika
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Electron density and temperature distributions in the H-1 heliac plasma are measured using the helium line intensity ratio technique based on a collisional-radiative model. An inversion approach with minimum Fisher regularization is developed to reconstruct the ratios of the local emission radiances from detected line-integrated intensities. The electron density and temperature inferred from the He I 667.8/728.1 and He I 728.1/706.5 nm line ratios are in good agreement with those from other diagnostic techniques in the inner region of the plasma. The electron density and temperature values appear to be a little high in the outer region of the plasma. Some possible causes of the discrepancy in the outer region are discussed.
ISSN:0034-6748
1089-7623