First measurement of electron temperature from signal ratios in a double-pass Thomson scattering system

This paper presents an experimental demonstration to determine electron temperature ( T e ) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scatte...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2012-02, Vol.83 (2), p.023507-023507-4
Hauptverfasser: Tojo, H., Ejiri, A., Hiratsuka, J., Yamaguchi, T., Takase, Y., Itami, K., Hatae, T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents an experimental demonstration to determine electron temperature ( T e ) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T e can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T e measured from the ratio ( T e,r ) and T e measured from a standard method ( T e,s ) showed a good agreement with 〈| T e,r − T e,s |/ T e,s 〉 = 7.3%.
ISSN:0034-6748
1089-7623
DOI:10.1063/1.3685612