Semi-Empirical Model of X-ray Tube Facility
A semi-empirical model of spectrum of X-ray tube was developed for the radiotherapy facility at the A.I. Burnazyan Federal Medical Biophysical Center for radiobiological experiments. The spectrum calculated by a programme EGSnrc was compared with the spectrum of the model. The results of the spectru...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A semi-empirical model of spectrum of X-ray tube was developed for the radiotherapy facility at the A.I. Burnazyan Federal Medical Biophysical Center for radiobiological experiments. The spectrum calculated by a programme EGSnrc was compared with the spectrum of the model. The results of the spectrum computations showed a good concord with the semi-empirical model. Comparison of the calculations of absorbed doses of the photon radiation in heterogeneous tissue phantoms for photon-capture therapy was done. |
---|---|
ISSN: | 0094-243X 1551-7616 |