Bench-Scale Studies of In-Duct Mercury Capture Using Cupric Chloride-Impregnated Carbons

A brominated activated carbon (Darco Hg-LH) and cupric chloride-impregnated activated carbon (CuCl2-ACs) sorbent have been tested in a bench-scale entrained-flow reactor system which was developed for simulating in-flight mercury capture in ducts upstream of particulate matter control devices. The b...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental science & technology 2009-04, Vol.43 (8), p.2957-2962
Hauptverfasser: Lee, Sang-Sup, Lee, Joo-Youp, Keener, Tim C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A brominated activated carbon (Darco Hg-LH) and cupric chloride-impregnated activated carbon (CuCl2-ACs) sorbent have been tested in a bench-scale entrained-flow reactor system which was developed for simulating in-flight mercury capture in ducts upstream of particulate matter control devices. The bench-scale experimental system has been operated with the conditions of a residence time of 0.75 s and a gas temperature of 140 °C to simulate typical conditions in the duct of coal-fired exhaust gas. In addition, sorbent deposition on walls which can occur in a laboratory-scale system more than in a full-scale system was significantly reduced so that additional mercury capture by the deposited sorbent was minimized. In the entrained-flow system, CuCl2-ACs demonstrated similar performance in Hg adsorption and better performance in Hg0 oxidation than Darco Hg-LH. In addition, the carbon content of those sorbents was found to determine their Hg adsorption capability in the entrained-flow system. The bench-scale entrained-flow system was able to demonstrate the important Hg adsorption and oxidation characteristics of the tested sorbents.
ISSN:0013-936X
1520-5851
DOI:10.1021/es801943t