K{sub Air} and H(10) Rate Constants for Gamma Emitters

Monte Carlo calculations have been carried out to estimate the Air Kerma rate constant and the Ambient dose equivalent rate constant for 139 monoenergetic photon sources. The factor that relates activity to air kerma rate or to ambient dose equivalent is useful to estimate the dose from a photon emi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIP conference proceedings 2008-08, Vol.1032 (1)
Hauptverfasser: Vega-Carrillo, H. R., Juarez, R. Rodriguez, Manzanares-Acuna, E., Davila, V. M. Hernandez, Mercado, G. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Monte Carlo calculations have been carried out to estimate the Air Kerma rate constant and the Ambient dose equivalent rate constant for 139 monoenergetic photon sources. The factor that relates activity to air kerma rate or to ambient dose equivalent is useful to estimate the dose from a photon emitter source. Here 139 point-like and monoenergetic gamma-ray sources, ranging from 0.01 to 10 MeV were utilized in Monte Carlo calculations to estimate both gamma factors. These factors were utilized to calculate the air kerma-and-ambient dose equivalent rate constants for {sup 137}Cs-{sup 137m}Ba, {sup 198}Au, {sup 60}Co, and {sup 131}I, whose values were compared with those published in the literature.
ISSN:0094-243X
1551-7616
DOI:10.1063/1.2979269