Percutaneous removal of a nonopaque silastic catheter from the pulmonary artery in two premature infants
A modified snare was made from a 0.016' guidewire and a 0.1-mm fishing string to remove a nonopaque Silastic catheter via a femoral vein approach in 2 premature infants at the 44th and 120th day of life, respectively. A foldover guidewire loop snare had failed in 1 infant before this technique...
Gespeichert in:
Veröffentlicht in: | Cardiovascular and interventional radiology 1997-07, Vol.20 (4), p.319-321 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A modified snare was made from a 0.016' guidewire and a 0.1-mm fishing string to remove a nonopaque Silastic catheter via a femoral vein approach in 2 premature infants at the 44th and 120th day of life, respectively. A foldover guidewire loop snare had failed in 1 infant before this technique was successfully applied. |
---|---|