Electronics and Algorithms for HOM Based Beam Diagnostics

The signals from the Higher Order Mode (HOM) ports on superconducting cavities can be used as beam position monitors and to do survey structure alignment. A HOM-based diagnostic system has been installed to instrument both couplers on each of the 40 cryogenic accelerating structures in the DESY TTF2...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIP conference proceedings 2006-01, Vol.868 (1), p.313-324
Hauptverfasser: Frisch, Josef, Baboi, Nicoleta, Eddy, Nathan, Nagaitsev, Sergei, Hensler, Olaf, McCormick, Douglas, May, Justin, Molloy, Stephen, Napoly, Olivier, Paparella, Rita, Petrosyan, Lyudvig, Ross, Marc, Simon, Claire, Smith, Tonee
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The signals from the Higher Order Mode (HOM) ports on superconducting cavities can be used as beam position monitors and to do survey structure alignment. A HOM-based diagnostic system has been installed to instrument both couplers on each of the 40 cryogenic accelerating structures in the DESY TTF2 Linac. The electronics uses a single stage down conversion from the 1.7 GHz HOM spectral line to a 20MHz IF which has been digitized. The electronics is based on low cost surface mount components suitable for large scale production. The analysis of the HOM data is based on Singular Value Decomposition. The response of the OM modes is calibrated using conventional BPMs.
ISSN:0094-243X
1551-7616
DOI:10.1063/1.2401419