In-vitro Study of the Dielectric Effects of X-Ray on Whole Human Blood
A comparative study was done to investigate the effects of the x-radiation on the electric properties of whole human blood, from healthy people. The x-ray source was set to 55 kV and 75 kV, in order to investigate power level effects on the samples. Short and long time effects were also investigated...
Gespeichert in:
Hauptverfasser: | , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A comparative study was done to investigate the effects of the x-radiation on the electric properties of whole human blood, from healthy people. The x-ray source was set to 55 kV and 75 kV, in order to investigate power level effects on the samples. Short and long time effects were also investigated. This experiment used a Solartron spectrometer to obtain the impedance response. No differences were found when samples were studied in the order of days (from one to five days), independently of the power level. Only in the case of 75 kV, in the power of the x-ray source, were detected significant differences between the dielectric properties of the blood, exposed to radiation, and its control sample, provided that the impedance spectrum were registered immediately after the exposure (after 15 or less minutes) |
---|---|
ISSN: | 0094-243X 1551-7616 |
DOI: | 10.1063/1.2356422 |