Visible bremsstrahlung tomographic diagnostic for the pulsed high density field-reversed configuration experiment
A diagnostic suite for the source section of the pulsed high density field-reversed configuration (FRC) experiment has been constructed to investigate the equilibrium and stability of FRC plasmas. In particular, a visible bremsstrahlung tomographic system has been designed and implemented. Three typ...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2006-10, Vol.77 (10), p.10F319-10F319-5 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A diagnostic suite for the source section of the pulsed high density field-reversed configuration (FRC) experiment has been constructed to investigate the equilibrium and stability of FRC plasmas. In particular, a visible bremsstrahlung tomographic system has been designed and implemented. Three types of tomographic analyses for FRCs are performed: a Fourier fit method (Cormack-Granetz), a maximum entropy method, and a minimum Fisher method utilizing code developed for the TCV tokamak experiment in Switzerland [
Anton
,
Plasma Phys. Controled Fusion
38
,
1849
(
1996
)
]. Results from the different methods and end-on imaging from the fast-framing camera are compared showing relative agreement of FRC internal structures between all measurements. |
---|---|
ISSN: | 0034-6748 1089-7623 |