High-energy point-projection radiography of a driven, shielded Hohlraum

Point projection backlighting is a high magnification, high resolution x-ray backlighting configuration that provides detailed images of large objects at a reduced energy budget compared to area backlighting. However, point projection backlighting has the drawback that the camera aperture is large a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2006-10, Vol.77 (10), p.10E324-10E324-3
Hauptverfasser: Keiter, Paul A., Workman, Jonathan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 10E324-3
container_issue 10
container_start_page 10E324
container_title Review of scientific instruments
container_volume 77
creator Keiter, Paul A.
Workman, Jonathan
description Point projection backlighting is a high magnification, high resolution x-ray backlighting configuration that provides detailed images of large objects at a reduced energy budget compared to area backlighting. However, point projection backlighting has the drawback that the camera aperture is large and open to more sources of noise. This issue has made it difficult to image driven targets without shielding. We present 9 keV x-ray images of the rear end of a driven Hohlraum that employs shielding. We also present data of a 10.3 keV x-ray image of an undriven Hohlraum .
doi_str_mv 10.1063/1.2351881
format Article
fullrecord <record><control><sourceid>scitation_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_20861204</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c312t-13ab304eb23962e15dc2b10e9b164cbed38ccc0626838aa7e3fa797e2763d7913</originalsourceid><addsrcrecordid>eNp1kEFLwzAYhoMoOKcH_0HBk2BmvqRL04sgopsw8KLnkCZf14ytKUkV9u9t7a5-l_fy8PJ-DyG3wBbApHiEBRdLUArOyAyYKmkhuTgnM8ZETmWRq0tyldKODbcEmJHV2m8bii3G7THrgm972sWwQ9v70GbROB-20XTNMQt1ZjIX_Q-2D1lqPO4dumwdmn0034drclGbfcKbU87J19vr58uabj5W7y_PG2oF8J6CMJVgOVZclJIjLJ3lFTAsK5C5rdAJZa1lkksllDEFitoUZYG8kMIVJYg5uZt6Q-q9Ttb3aBsb2nZYrDlTEjjLB-p-omwMKUWsdRf9wcSjBqZHTxr0ydPAPk3sWGbGt_-HR1l6kqX_ZA2o-AVm6W8V</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>High-energy point-projection radiography of a driven, shielded Hohlraum</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><creator>Keiter, Paul A. ; Workman, Jonathan</creator><creatorcontrib>Keiter, Paul A. ; Workman, Jonathan</creatorcontrib><description>Point projection backlighting is a high magnification, high resolution x-ray backlighting configuration that provides detailed images of large objects at a reduced energy budget compared to area backlighting. However, point projection backlighting has the drawback that the camera aperture is large and open to more sources of noise. This issue has made it difficult to image driven targets without shielding. We present 9 keV x-ray images of the rear end of a driven Hohlraum that employs shielding. We also present data of a 10.3 keV x-ray image of an undriven Hohlraum .</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.2351881</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>APERTURES ; CAMERAS ; CONFIGURATION ; INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; KEV RANGE 01-10 ; KEV RANGE 10-100 ; NOISE ; RESOLUTION ; SHIELDING ; X RADIATION</subject><ispartof>Review of scientific instruments, 2006-10, Vol.77 (10), p.10E324-10E324-3</ispartof><rights>2006 American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c312t-13ab304eb23962e15dc2b10e9b164cbed38ccc0626838aa7e3fa797e2763d7913</citedby><cites>FETCH-LOGICAL-c312t-13ab304eb23962e15dc2b10e9b164cbed38ccc0626838aa7e3fa797e2763d7913</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.2351881$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>230,314,780,784,794,885,1559,4512,27924,27925,76384,76390</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/20861204$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Keiter, Paul A.</creatorcontrib><creatorcontrib>Workman, Jonathan</creatorcontrib><title>High-energy point-projection radiography of a driven, shielded Hohlraum</title><title>Review of scientific instruments</title><description>Point projection backlighting is a high magnification, high resolution x-ray backlighting configuration that provides detailed images of large objects at a reduced energy budget compared to area backlighting. However, point projection backlighting has the drawback that the camera aperture is large and open to more sources of noise. This issue has made it difficult to image driven targets without shielding. We present 9 keV x-ray images of the rear end of a driven Hohlraum that employs shielding. We also present data of a 10.3 keV x-ray image of an undriven Hohlraum .</description><subject>APERTURES</subject><subject>CAMERAS</subject><subject>CONFIGURATION</subject><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>KEV RANGE 01-10</subject><subject>KEV RANGE 10-100</subject><subject>NOISE</subject><subject>RESOLUTION</subject><subject>SHIELDING</subject><subject>X RADIATION</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp1kEFLwzAYhoMoOKcH_0HBk2BmvqRL04sgopsw8KLnkCZf14ytKUkV9u9t7a5-l_fy8PJ-DyG3wBbApHiEBRdLUArOyAyYKmkhuTgnM8ZETmWRq0tyldKODbcEmJHV2m8bii3G7THrgm972sWwQ9v70GbROB-20XTNMQt1ZjIX_Q-2D1lqPO4dumwdmn0034drclGbfcKbU87J19vr58uabj5W7y_PG2oF8J6CMJVgOVZclJIjLJ3lFTAsK5C5rdAJZa1lkksllDEFitoUZYG8kMIVJYg5uZt6Q-q9Ttb3aBsb2nZYrDlTEjjLB-p-omwMKUWsdRf9wcSjBqZHTxr0ydPAPk3sWGbGt_-HR1l6kqX_ZA2o-AVm6W8V</recordid><startdate>20061001</startdate><enddate>20061001</enddate><creator>Keiter, Paul A.</creator><creator>Workman, Jonathan</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>20061001</creationdate><title>High-energy point-projection radiography of a driven, shielded Hohlraum</title><author>Keiter, Paul A. ; Workman, Jonathan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c312t-13ab304eb23962e15dc2b10e9b164cbed38ccc0626838aa7e3fa797e2763d7913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>APERTURES</topic><topic>CAMERAS</topic><topic>CONFIGURATION</topic><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>KEV RANGE 01-10</topic><topic>KEV RANGE 10-100</topic><topic>NOISE</topic><topic>RESOLUTION</topic><topic>SHIELDING</topic><topic>X RADIATION</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Keiter, Paul A.</creatorcontrib><creatorcontrib>Workman, Jonathan</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Keiter, Paul A.</au><au>Workman, Jonathan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High-energy point-projection radiography of a driven, shielded Hohlraum</atitle><jtitle>Review of scientific instruments</jtitle><date>2006-10-01</date><risdate>2006</risdate><volume>77</volume><issue>10</issue><spage>10E324</spage><epage>10E324-3</epage><pages>10E324-10E324-3</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Point projection backlighting is a high magnification, high resolution x-ray backlighting configuration that provides detailed images of large objects at a reduced energy budget compared to area backlighting. However, point projection backlighting has the drawback that the camera aperture is large and open to more sources of noise. This issue has made it difficult to image driven targets without shielding. We present 9 keV x-ray images of the rear end of a driven Hohlraum that employs shielding. We also present data of a 10.3 keV x-ray image of an undriven Hohlraum .</abstract><cop>United States</cop><pub>American Institute of Physics</pub><doi>10.1063/1.2351881</doi></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2006-10, Vol.77 (10), p.10E324-10E324-3
issn 0034-6748
1089-7623
language eng
recordid cdi_osti_scitechconnect_20861204
source AIP Journals Complete; AIP Digital Archive
subjects APERTURES
CAMERAS
CONFIGURATION
INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
KEV RANGE 01-10
KEV RANGE 10-100
NOISE
RESOLUTION
SHIELDING
X RADIATION
title High-energy point-projection radiography of a driven, shielded Hohlraum
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T13%3A11%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High-energy%20point-projection%20radiography%20of%20a%20driven,%20shielded%20Hohlraum&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Keiter,%20Paul%20A.&rft.date=2006-10-01&rft.volume=77&rft.issue=10&rft.spage=10E324&rft.epage=10E324-3&rft.pages=10E324-10E324-3&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.2351881&rft_dat=%3Cscitation_osti_%3Ersi%3C/scitation_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true