Physical Insights and Test Stand Results for the LANSCE H- Surface Converter Source
The Los Alamos Neutron Science Center (LANSCE) H- surface converter source upgrade project has been ongoing for several years to reach 25-40 mA current with 7(cm-mrad) lab emittance (95% beam fraction). The duty factor is 12% (120 Hz, 1ms pulse length). Summary test stand results and interpretations...
Gespeichert in:
Hauptverfasser: | , , , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The Los Alamos Neutron Science Center (LANSCE) H- surface converter source upgrade project has been ongoing for several years to reach 25-40 mA current with 7(cm-mrad) lab emittance (95% beam fraction). The duty factor is 12% (120 Hz, 1ms pulse length). Summary test stand results and interpretations for a six filament axial extraction H- source are presented. This source did produce 40-mA H- current, but with unacceptable emittance growth. More recently a fourth modified LANSCE H- production source with radial H- extraction system has been constructed, and is presently undergoing tests. Currents up to 25mA H- have been observed with 20% emittance growth. This emittance growth may be acceptable for 800 MeV linac operations. A summary of physical principles of emittance growth mechanisms and converter physics are given. |
---|---|
ISSN: | 0094-243X 1551-7616 |