Physical Insights and Test Stand Results for the LANSCE H- Surface Converter Source

The Los Alamos Neutron Science Center (LANSCE) H- surface converter source upgrade project has been ongoing for several years to reach 25-40 mA current with 7(cm-mrad) lab emittance (95% beam fraction). The duty factor is 12% (120 Hz, 1ms pulse length). Summary test stand results and interpretations...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sherman, Joseph, Chacon-Golcher, Edwin, Geros, Ernest G, Jacobson, Edward, Lara, Patrick, Meyer, Bruce J, Naffziger, Peter, Rouleau, Gary, Schaller, Stuart C, Stevens Jr, Ralph R, Zaugg, Thomas
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The Los Alamos Neutron Science Center (LANSCE) H- surface converter source upgrade project has been ongoing for several years to reach 25-40 mA current with 7(cm-mrad) lab emittance (95% beam fraction). The duty factor is 12% (120 Hz, 1ms pulse length). Summary test stand results and interpretations for a six filament axial extraction H- source are presented. This source did produce 40-mA H- current, but with unacceptable emittance growth. More recently a fourth modified LANSCE H- production source with radial H- extraction system has been constructed, and is presently undergoing tests. Currents up to 25mA H- have been observed with 20% emittance growth. This emittance growth may be acceptable for 800 MeV linac operations. A summary of physical principles of emittance growth mechanisms and converter physics are given.
ISSN:0094-243X
1551-7616
DOI:10.1063/1.1908301