Laser-induced thermal-acoustic velocimetry with heterodyne detection

Laser-induced thermal acoustics (LITA) was used with heterodyne detection to measure simultaneously and in a single laser pulse the sound speed and flow velocity of NO>(2) -seeded air in a low-speed wind tunnel up to Mach number M =0.1 . The uncertainties of the velocity and the sound speed measu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics letters 2000-02, Vol.25 (4), p.224-226
Hauptverfasser: Schlamp, S, Cummings, E B, Sobota, T H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Laser-induced thermal acoustics (LITA) was used with heterodyne detection to measure simultaneously and in a single laser pulse the sound speed and flow velocity of NO>(2) -seeded air in a low-speed wind tunnel up to Mach number M =0.1 . The uncertainties of the velocity and the sound speed measurements were ~0.2 m/s and 0.5%, respectively. Measurements were obtained through a nonlinear least-squares fit to a general, analytic closed-form solution for heterodyne-detected LITA signals from thermal gratings. Agreement between theory and experiment is exceptionally good.
ISSN:0146-9592
1539-4794
DOI:10.1364/OL.25.000224