Oxygen diffusion coefficient and solubility in a new proton exchange membrane
The electrochemical monitoring technique is used to measure the solubility and the diffusion coefficient of oxygen in a new proton exchange membrane that is being developed by Cape Cod Research, Inc., Using the method of least squares, the data were fit to an analytical solution of Fick's secon...
Gespeichert in:
Veröffentlicht in: | Journal of the Electrochemical Society 2000-03, Vol.147 (3), p.980-983 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The electrochemical monitoring technique is used to measure the solubility and the diffusion coefficient of oxygen in a new proton exchange membrane that is being developed by Cape Cod Research, Inc., Using the method of least squares, the data were fit to an analytical solution of Fick's second law to determine D and c{sub 0}. Values of 0.40 x 10{sup {minus}6}cm{sup 2}/s and 4.98 x 10{sup {minus}6} mol/cm{sup 3} were obtained for the diffusion coefficient and solubility, respectively, of the Cape Cod membrane. These values are significantly less than those of Nafion 117 tested under identical conditions. |
---|---|
ISSN: | 0013-4651 1945-7111 |
DOI: | 10.1149/1.1393300 |