Europium diffusion in IG-110 nuclear graphite

Europium diffusion in graphite has been recognized to be of interest in high-temperature gas reactor safety analysis, particularly as an indicator of strontium diffusion. However, no measurements of europium diffusion coefficients have been reported in the literature. In this work, the effective dif...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of nuclear materials 2022-04, Vol.561 (C), p.153544, Article 153544
Hauptverfasser: Weilert, T.M., Walton, K.L., Loyalka, S.K., Brockman, J.D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Europium diffusion in graphite has been recognized to be of interest in high-temperature gas reactor safety analysis, particularly as an indicator of strontium diffusion. However, no measurements of europium diffusion coefficients have been reported in the literature. In this work, the effective diffusion coefficient of europium was measured using a time-release method. Natural europium was loaded into pre-milled unirradiated IG-110 graphite spheres using a pressurized acid digestion vessel. The time-release experiments were performed in the temperature range 1823 K – 1973 K using a SiC diffusion cell connected to an inductively-coupled plasma mass spectrometer (ICP-MS) via a He gas line. The results of this work are: DEu,IG−110=(1.5×10−3m2/s)exp(−2.87×105J/molRT)This effective diffusion coefficient can be used to aid in predictive modelling of europium transport in HTGRs.
ISSN:0022-3115
1873-4820
DOI:10.1016/j.jnucmat.2022.153544