Performance study of a 3×1×1 m3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m3) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JINST 2021-08, Vol.16 (8)
Hauptverfasser: Aimard, B., Aizawa, L., Aushev, V., Autiero, D., Balleyguier, L., Bechetoille, E., Belver, D., Bordoni, S., Bourgeois, N., Bourguille, B., Brunetti, G., Caiulo, D., Calin, M., Campanelli, M., Cankocak, K., Cantini, C., Cautisanu, B.M., Charitonidis, N., Chatterjee, A., Chiriacescuf, A., Chiu, P., Conforti, S., Crivelli, P., Cuesta, C., Dawson, J., De La Taille, C., Doizon, F., Duchesneau, D., Dulucq, F., Duval, F., Emery, S., Ereditato, A., Fusshoeller, K., Gallego-Ros, A., Geffroy, N., Gherghel-Lascu, A., Gil-Botella, I., Girerd, C., Gomoiu, M.C., Gorodetzky, P., Hanni, R., Hasegawa, T., Holin, A., Horikawa, S., Ikeno, M., Jipa, A., Karolak, M., Karyotakis, Y., Kasai, S., Kishishita, T., Konari, H., Kryn, D., Kuromori, Y., Lastoria, C., Lehmann-Miotto, G., Leyton, M., Liubarska, M., Loo, K., Lorca, D., Lutz, P., Lux, T., Maire, G., Maki, M., Mathez, H., Mazzucato, E., Mosu, T.S., Mu, W., Murphy, S., Nakayoshi, K., Navas-Nicolás, D., Niculescu-Oglinzanu, M., Palomares, C., Parvu, M., Patzak, T., Penichot, Y., Pennacchio, E., Pessard, H., Pietropaolo, F., Pugnere, D., Radics, B., Redondo, D., Regenfus, C., Resnati, F., Ristea, O., Rubbia, A., Santos, C., Sergiampietri, F., Shahsavarani, S., Shoji, M., Soto-Oton, J., Sulej, R., Toboaru, V., Trzaska, W.H., Urda, L., Vasseur, G., Viant, T., Vihonen, S., Weber, M., Wu, S., Yu, J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m3) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/16/08/P08063