Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

We describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of instrumentation 2020-03, Vol.15 (3), p.P03022-P03022, Article P03022
Hauptverfasser: Adams, C., Alrashed, M., An, R., Anthony, J., Asaadi, J., Ashkenazi, A., Balasubramanian, S., Baller, B., Barnes, C., Barr, G., Basque, V., Bass, M., Bay, F., Berkman, S., Bhanderi, A., Bhat, A., Bishai, M., Blake, A., Bolton, T., Camilleri, L., Caratelli, D., Terrazas, I. Caro, Carr, R., Fernandez, R. Castillo, Cavanna, F., Cerati, G., Chen, Y., Church, E., Cianci, D., Cohen, E.O., Conrad, J.M., Convery, M., Cooper-Troendle, L., Crespo-Anadón, J.I., Tutto, M. Del, Devitt, D., Diaz, A., Domine, L., Duffy, K., Dytman, S., Eberly, B., Ereditato, A., Sanchez, L. Escudero, Esquivel, J., Evans, J.J., Fitzpatrick, R.S., Fleming, B.T., Foppiani, N., Franco, D., Furmanski, A.P., Garcia-Gamez, D., Gardiner, S., Genty, V., Goeldi, D., Gollapinni, S., Goodwin, O., Gramellini, E., Green, P., Greenlee, H., Grosso, R., Gu, L., Gu, W., Guenette, R., Guzowski, P., Hamilton, P., Hen, O., Hill, C., Horton-Smith, G.A., Hourlier, A., Huang, E.-C., Itay, R., James, C., de Vries, J. Jan, Ji, X., Jiang, L., Jo, J.H., Johnson, R.A., Joshi, J., Jwa, Y.-J., Karagiorgi, G., Ketchum, W., Kirby, B., Kirby, M., Kobilarcik, T., Kreslo, I., Lepetic, I., Li, Y., Lister, A., Littlejohn, B.R., Lockwitz, S., Lorca, D., Louis, W.C., Luethi, M., Lundberg, B., Luo, X., Marchionni, A., Marcocci, S., Mariani, C., Marshall, J., Martin-Albo, J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/15/03/P03022