Limits of special material detectability fundamental to idealized dual-energy radiographic systems
Analysis of dual-energy radiographic approaches to the detection of “special” material, i.e. contraband, in otherwise innocuous scenes, such as maritime cargo containers encountered at ports of entry, reveals fundamental limitations of data obtained along a single line-of-sight. The basic equations...
Gespeichert in:
Veröffentlicht in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2019-11, Vol.944 (C), p.162563, Article 162563 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Analysis of dual-energy radiographic approaches to the detection of “special” material, i.e. contraband, in otherwise innocuous scenes, such as maritime cargo containers encountered at ports of entry, reveals fundamental limitations of data obtained along a single line-of-sight. The basic equations that describe idealized systems are presented and analyzed so as to identify challenges that are only exacerbated by scatter, noise, and measurement uncertainty. In the mono-energetic limit, the instrumentation and measurement techniques reduce to a system of linear equations that are simple to treat: it is shown that there exists a threshold for the minimum amount of high-Z material that can be detected unambiguously (without the risk of false positive or false negative indications), even when the background materials are of finite and of well-known variety. The threshold depends on the quality of prior information about the cargo and the selection of probing energies, and can therefore be minimized by good system design practices and measurement procedures, but persists as a general challenge to security operations. In discussion of this result, it is noted that techniques incorporating other prior information, such as the geometry of cargo and potential contraband, along with data from 2D imaging, have far greater potential. As an example, a simple data analysis method capable of differentiating high-Z spheres from those of more common material is presented. This simple example demonstrates that, although simple line-of-sight transmission radiography may suffer fundamental limitations, there remains good cause to be optimistic about the potential for image analysis in radiographic material identification. |
---|---|
ISSN: | 0168-9002 1872-9576 |
DOI: | 10.1016/j.nima.2019.162563 |