Measuring the attenuation length of water in the CHIPS-M water Cherenkov detector

The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in con...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nucl.Instrum.Meth.A 2017-02, Vol.844 (C), p.108-115
Hauptverfasser: Amat, F., Bizouard, P., Bryant, J., Carroll, T.J., Rijck, S. De, Germani, S., Joyce, T., Kriesten, B., Marshak, M., Meier, J., Nelson, J.K., Perch, A.J., Pfützner, M.M., Salazar, R., Thomas, J., Trokan-Tenorio, J., Vahle, P., Wade, R., Wendt, C., Whitehead, L.H., Whitney, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2m vertical column filled with this water, was used to study the transmission of 405nm laser light. Results consistent with attenuation lengths of up to 100m were observed for this wavelength with filtration and UV sterilization alone.
ISSN:0168-9002
1872-9576
DOI:10.1016/j.nima.2016.11.032