The solvent extraction of Am(VI) using centrifugal contactors

An engineering-scale centrifugal contactor test bed was built at Idaho National Laboratory to perform solvent extraction testing for the partitioning of hexavalent americium. The raffinate simulant feed was spiked with 243 Am and 139 Ce and treated with sodium bismuthate to oxidize americium to Am(V...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of radioanalytical and nuclear chemistry 2016-03, Vol.307 (3), p.1833-1836
Hauptverfasser: Mincher, Bruce J., Tillotson, Richard D., Garn, Troy, Rutledge, Veronica, Law, Jack, Schmitt, Nicholas C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An engineering-scale centrifugal contactor test bed was built at Idaho National Laboratory to perform solvent extraction testing for the partitioning of hexavalent americium. The raffinate simulant feed was spiked with 243 Am and 139 Ce and treated with sodium bismuthate to oxidize americium to Am(VI), filtered and contacted with 1 M DAAP/dodecane using centrifugal contactors. Extraction efficiency comparable to batch contacts was obtained, indicating for the first time that Am(VI) can be maintained under process conditions. Contrary to expectations, stripping was not as effective as expected. However, this result may actually be advantageous to process design, since a scrub step, previously thought to be impossible due to rapid Am(VI) reduction, may now be considered for future flowsheet tests.
ISSN:0236-5731
1588-2780
DOI:10.1007/s10967-015-4397-6