Investigation of formaldehyde and acetaldehyde sampling rate and ozone interference for passive deployment of Waters Sep-Pak XPoSure samplers

This study investigated formaldehyde and acetaldehyde passive sampling rates and ozone interference for the DNPH-based Waters Sep-Pak XPoSure sampler. Previous studies have shown that ozone interferes with active sampling by this cartridge. Our study included one laboratory and six field experiments...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Atmospheric environment (1994) 2013-12, Vol.80, p.184-189
Hauptverfasser: Mullen, Nasim A., Russell, Marion L., Lunden, Melissa M., Singer, Brett C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 189
container_issue
container_start_page 184
container_title Atmospheric environment (1994)
container_volume 80
creator Mullen, Nasim A.
Russell, Marion L.
Lunden, Melissa M.
Singer, Brett C.
description This study investigated formaldehyde and acetaldehyde passive sampling rates and ozone interference for the DNPH-based Waters Sep-Pak XPoSure sampler. Previous studies have shown that ozone interferes with active sampling by this cartridge. Our study included one laboratory and six field experiments conducted in Northern California homes. Passive sampling rates of 1.10 ± 0.09 and 0.86 ± 0.10 mL min−1 determined for formaldehyde and acetaldehyde are lower than previously reported. In a controlled laboratory experiment there were small, statistically insignificant impacts of subsequent ozone exposure on formaldehyde and acetaldehyde mass passively collected on the samplers. This sampler is inexpensive, easy to deploy and to transport by mail, and has a high sampling capacity when used passively; it is suitable for a wide-range of monitoring applications. However, the passive sampling rate remains in question given the internally consistent, but different results obtained in our study and the previous study.
doi_str_mv 10.1016/j.atmosenv.2013.07.074
format Article
fullrecord <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1165270</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1352231013006079</els_id><sourcerecordid>S1352231013006079</sourcerecordid><originalsourceid>FETCH-LOGICAL-c417t-a39dff6f35f7e11f65b0a1ed3f3f077f69a3da9fe1d1ed26d31f8077871c056d3</originalsourceid><addsrcrecordid>eNqFUM1q3DAQNqWBppu-QhCFHL2VLNuyby0hTRcCCWxCehMTaZRoa0tGUhc275B3rozTXAMDkub70cxXFKeMrhll7bfdGtLoI7r9uqKMr6nIVX8ojlkneFl1df0x33lTlRVn9FPxOcYdpZSLXhwXLxu3x5jsIyTrHfGGGB9GGDQ-HTQScJqAwvTWiDBOg3WPJEBaYP_sHRLrEgaDAZ3C2YJMEKPdI9E4Df4wokuz-X1WhUi2OJU38If8vvHbv-HVNQMnxZGBIeKX13NV3P28uD3_VV5dX27Of1yVqmYilcB7bUxreGMEMmba5oECQ80NN1QI0_bANfQGmc7dqtWcmS4DnWCKNvm5Kr4uvj6vLqOyCdWT8s6hSpKxtqkEzaR2IangYwxo5BTsCOEgGZVz8nIn_ycv5-QlFbnqLDxbhDkDBYMJ4JSNb-pKdJxWfZt53xce5lX3FsM8yRygtmEeRHv73lf_ANpqoSc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Investigation of formaldehyde and acetaldehyde sampling rate and ozone interference for passive deployment of Waters Sep-Pak XPoSure samplers</title><source>Access via ScienceDirect (Elsevier)</source><creator>Mullen, Nasim A. ; Russell, Marion L. ; Lunden, Melissa M. ; Singer, Brett C.</creator><creatorcontrib>Mullen, Nasim A. ; Russell, Marion L. ; Lunden, Melissa M. ; Singer, Brett C. ; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</creatorcontrib><description>This study investigated formaldehyde and acetaldehyde passive sampling rates and ozone interference for the DNPH-based Waters Sep-Pak XPoSure sampler. Previous studies have shown that ozone interferes with active sampling by this cartridge. Our study included one laboratory and six field experiments conducted in Northern California homes. Passive sampling rates of 1.10 ± 0.09 and 0.86 ± 0.10 mL min−1 determined for formaldehyde and acetaldehyde are lower than previously reported. In a controlled laboratory experiment there were small, statistically insignificant impacts of subsequent ozone exposure on formaldehyde and acetaldehyde mass passively collected on the samplers. This sampler is inexpensive, easy to deploy and to transport by mail, and has a high sampling capacity when used passively; it is suitable for a wide-range of monitoring applications. However, the passive sampling rate remains in question given the internally consistent, but different results obtained in our study and the previous study.</description><identifier>ISSN: 1352-2310</identifier><identifier>EISSN: 1873-2844</identifier><identifier>DOI: 10.1016/j.atmosenv.2013.07.074</identifier><language>eng</language><publisher>Kidlington: Elsevier Ltd</publisher><subject>Aldehyde ; Analysis methods ; Applied sciences ; Atmospheric pollution ; ENVIRONMENTAL SCIENCES ; Exact sciences and technology ; Exposure ; Indoor air quality ; Passive sampler ; Pollution ; Residential</subject><ispartof>Atmospheric environment (1994), 2013-12, Vol.80, p.184-189</ispartof><rights>2013 Elsevier Ltd</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c417t-a39dff6f35f7e11f65b0a1ed3f3f077f69a3da9fe1d1ed26d31f8077871c056d3</citedby><cites>FETCH-LOGICAL-c417t-a39dff6f35f7e11f65b0a1ed3f3f077f69a3da9fe1d1ed26d31f8077871c056d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.atmosenv.2013.07.074$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=27830296$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/servlets/purl/1165270$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Mullen, Nasim A.</creatorcontrib><creatorcontrib>Russell, Marion L.</creatorcontrib><creatorcontrib>Lunden, Melissa M.</creatorcontrib><creatorcontrib>Singer, Brett C.</creatorcontrib><creatorcontrib>Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</creatorcontrib><title>Investigation of formaldehyde and acetaldehyde sampling rate and ozone interference for passive deployment of Waters Sep-Pak XPoSure samplers</title><title>Atmospheric environment (1994)</title><description>This study investigated formaldehyde and acetaldehyde passive sampling rates and ozone interference for the DNPH-based Waters Sep-Pak XPoSure sampler. Previous studies have shown that ozone interferes with active sampling by this cartridge. Our study included one laboratory and six field experiments conducted in Northern California homes. Passive sampling rates of 1.10 ± 0.09 and 0.86 ± 0.10 mL min−1 determined for formaldehyde and acetaldehyde are lower than previously reported. In a controlled laboratory experiment there were small, statistically insignificant impacts of subsequent ozone exposure on formaldehyde and acetaldehyde mass passively collected on the samplers. This sampler is inexpensive, easy to deploy and to transport by mail, and has a high sampling capacity when used passively; it is suitable for a wide-range of monitoring applications. However, the passive sampling rate remains in question given the internally consistent, but different results obtained in our study and the previous study.</description><subject>Aldehyde</subject><subject>Analysis methods</subject><subject>Applied sciences</subject><subject>Atmospheric pollution</subject><subject>ENVIRONMENTAL SCIENCES</subject><subject>Exact sciences and technology</subject><subject>Exposure</subject><subject>Indoor air quality</subject><subject>Passive sampler</subject><subject>Pollution</subject><subject>Residential</subject><issn>1352-2310</issn><issn>1873-2844</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNqFUM1q3DAQNqWBppu-QhCFHL2VLNuyby0hTRcCCWxCehMTaZRoa0tGUhc275B3rozTXAMDkub70cxXFKeMrhll7bfdGtLoI7r9uqKMr6nIVX8ojlkneFl1df0x33lTlRVn9FPxOcYdpZSLXhwXLxu3x5jsIyTrHfGGGB9GGDQ-HTQScJqAwvTWiDBOg3WPJEBaYP_sHRLrEgaDAZ3C2YJMEKPdI9E4Df4wokuz-X1WhUi2OJU38If8vvHbv-HVNQMnxZGBIeKX13NV3P28uD3_VV5dX27Of1yVqmYilcB7bUxreGMEMmba5oECQ80NN1QI0_bANfQGmc7dqtWcmS4DnWCKNvm5Kr4uvj6vLqOyCdWT8s6hSpKxtqkEzaR2IangYwxo5BTsCOEgGZVz8nIn_ycv5-QlFbnqLDxbhDkDBYMJ4JSNb-pKdJxWfZt53xce5lX3FsM8yRygtmEeRHv73lf_ANpqoSc</recordid><startdate>20131201</startdate><enddate>20131201</enddate><creator>Mullen, Nasim A.</creator><creator>Russell, Marion L.</creator><creator>Lunden, Melissa M.</creator><creator>Singer, Brett C.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>OIOZB</scope><scope>OTOTI</scope></search><sort><creationdate>20131201</creationdate><title>Investigation of formaldehyde and acetaldehyde sampling rate and ozone interference for passive deployment of Waters Sep-Pak XPoSure samplers</title><author>Mullen, Nasim A. ; Russell, Marion L. ; Lunden, Melissa M. ; Singer, Brett C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c417t-a39dff6f35f7e11f65b0a1ed3f3f077f69a3da9fe1d1ed26d31f8077871c056d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Aldehyde</topic><topic>Analysis methods</topic><topic>Applied sciences</topic><topic>Atmospheric pollution</topic><topic>ENVIRONMENTAL SCIENCES</topic><topic>Exact sciences and technology</topic><topic>Exposure</topic><topic>Indoor air quality</topic><topic>Passive sampler</topic><topic>Pollution</topic><topic>Residential</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mullen, Nasim A.</creatorcontrib><creatorcontrib>Russell, Marion L.</creatorcontrib><creatorcontrib>Lunden, Melissa M.</creatorcontrib><creatorcontrib>Singer, Brett C.</creatorcontrib><creatorcontrib>Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>OSTI.GOV - Hybrid</collection><collection>OSTI.GOV</collection><jtitle>Atmospheric environment (1994)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mullen, Nasim A.</au><au>Russell, Marion L.</au><au>Lunden, Melissa M.</au><au>Singer, Brett C.</au><aucorp>Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Investigation of formaldehyde and acetaldehyde sampling rate and ozone interference for passive deployment of Waters Sep-Pak XPoSure samplers</atitle><jtitle>Atmospheric environment (1994)</jtitle><date>2013-12-01</date><risdate>2013</risdate><volume>80</volume><spage>184</spage><epage>189</epage><pages>184-189</pages><issn>1352-2310</issn><eissn>1873-2844</eissn><abstract>This study investigated formaldehyde and acetaldehyde passive sampling rates and ozone interference for the DNPH-based Waters Sep-Pak XPoSure sampler. Previous studies have shown that ozone interferes with active sampling by this cartridge. Our study included one laboratory and six field experiments conducted in Northern California homes. Passive sampling rates of 1.10 ± 0.09 and 0.86 ± 0.10 mL min−1 determined for formaldehyde and acetaldehyde are lower than previously reported. In a controlled laboratory experiment there were small, statistically insignificant impacts of subsequent ozone exposure on formaldehyde and acetaldehyde mass passively collected on the samplers. This sampler is inexpensive, easy to deploy and to transport by mail, and has a high sampling capacity when used passively; it is suitable for a wide-range of monitoring applications. However, the passive sampling rate remains in question given the internally consistent, but different results obtained in our study and the previous study.</abstract><cop>Kidlington</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.atmosenv.2013.07.074</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1352-2310
ispartof Atmospheric environment (1994), 2013-12, Vol.80, p.184-189
issn 1352-2310
1873-2844
language eng
recordid cdi_osti_scitechconnect_1165270
source Access via ScienceDirect (Elsevier)
subjects Aldehyde
Analysis methods
Applied sciences
Atmospheric pollution
ENVIRONMENTAL SCIENCES
Exact sciences and technology
Exposure
Indoor air quality
Passive sampler
Pollution
Residential
title Investigation of formaldehyde and acetaldehyde sampling rate and ozone interference for passive deployment of Waters Sep-Pak XPoSure samplers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T05%3A48%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Investigation%20of%20formaldehyde%20and%20acetaldehyde%20sampling%20rate%20and%20ozone%20interference%20for%20passive%20deployment%20of%20Waters%20Sep-Pak%20XPoSure%20samplers&rft.jtitle=Atmospheric%20environment%20(1994)&rft.au=Mullen,%20Nasim%20A.&rft.aucorp=Lawrence%20Berkeley%20National%20Lab.%20(LBNL),%20Berkeley,%20CA%20(United%20States)&rft.date=2013-12-01&rft.volume=80&rft.spage=184&rft.epage=189&rft.pages=184-189&rft.issn=1352-2310&rft.eissn=1873-2844&rft_id=info:doi/10.1016/j.atmosenv.2013.07.074&rft_dat=%3Celsevier_osti_%3ES1352231013006079%3C/elsevier_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S1352231013006079&rfr_iscdi=true