Fundamental Resolution Limits during Electron-Induced Direct-Write Synthesis

In this study, we focus on the resolution limits for quasi 2-D single lines synthesized via focused electron-beam-induced direct-write deposition at 5 and 30 keV in a scanning electron microscope. To understand the relevant proximal broadening effects, the substrates were thicker than the beam penet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ACS applied materials & interfaces 2014-05, Vol.6 (10), p.7380-7387
Hauptverfasser: Arnold, Georg, Timilsina, Rajendra, Fowlkes, Jason, Orthacker, Angelina, Kothleitner, Gerald, Rack, Philip D, Plank, Harald
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, we focus on the resolution limits for quasi 2-D single lines synthesized via focused electron-beam-induced direct-write deposition at 5 and 30 keV in a scanning electron microscope. To understand the relevant proximal broadening effects, the substrates were thicker than the beam penetration depth and we used the MeCpPt­(IV)­Me3 precursor under standard gas injection system conditions. It is shown by experiment and simulation how backscatter electron yields increase during the initial growth stages which broaden the single lines consistent with the backscatter range of the deposited material. By this it is shown that the beam diameter together with the evolving backscatter radius of the deposit material determines the achievable line widths even for ultrathin deposit heights in the sub-5-nm regime.
ISSN:1944-8244
1944-8252
DOI:10.1021/am5008003