In situ detection and analysis of laser-induced damage on a 1.5-m multilayer-dielectric grating compressor for high-energy, petawatt-class laser systems

A grating-inspection system and a damage-analysis method have been developed to measure in situ laser-induced damage on a 1.5-m tiled-grating assembly of the OMEGA EP pulse compressor during a 15-ps, 2.2-kJ energy ramp. The beam fluence at which significant damage growth occurred was determined. Thi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2010-05, Vol.18 (10), p.10423-10431
Hauptverfasser: Qiao, J, Schmid, A W, Waxer, L J, Nguyen, T, Bunkenburg, J, Kingsley, C, Kozlov, A, Weiner, D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A grating-inspection system and a damage-analysis method have been developed to measure in situ laser-induced damage on a 1.5-m tiled-grating assembly of the OMEGA EP pulse compressor during a 15-ps, 2.2-kJ energy ramp. The beam fluence at which significant damage growth occurred was determined. This is the first report on beam fluence versus laser-induced-damage growth of meter-sized multilayer-dielectric-diffraction gratings. This result was correlated to the damage-probability measurement conducted on a small grating sample and is consistent with the fluence, corresponding to 100% damage probability.
ISSN:1094-4087
1094-4087
DOI:10.1364/OE.18.010423