In situ detection and analysis of laser-induced damage on a 1.5-m multilayer-dielectric grating compressor for high-energy, petawatt-class laser systems
A grating-inspection system and a damage-analysis method have been developed to measure in situ laser-induced damage on a 1.5-m tiled-grating assembly of the OMEGA EP pulse compressor during a 15-ps, 2.2-kJ energy ramp. The beam fluence at which significant damage growth occurred was determined. Thi...
Gespeichert in:
Veröffentlicht in: | Optics express 2010-05, Vol.18 (10), p.10423-10431 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A grating-inspection system and a damage-analysis method have been developed to measure in situ laser-induced damage on a 1.5-m tiled-grating assembly of the OMEGA EP pulse compressor during a 15-ps, 2.2-kJ energy ramp. The beam fluence at which significant damage growth occurred was determined. This is the first report on beam fluence versus laser-induced-damage growth of meter-sized multilayer-dielectric-diffraction gratings. This result was correlated to the damage-probability measurement conducted on a small grating sample and is consistent with the fluence, corresponding to 100% damage probability. |
---|---|
ISSN: | 1094-4087 1094-4087 |
DOI: | 10.1364/OE.18.010423 |