Anterior cruciate ligament femoral-tunnel drilling through an anteromedial portal: 3-dimensional plane drilling angle affects tunnel length relative to notchplasty
Notchplasty is a surgical technique often performed during anterior cruciate ligament reconstruction (ACLR) with widening of the intercondylar notch of the lateral distal femur to avoid graft impingement. The purpose of this study was to correlate femoral-tunnel length with 3-dimensional (3D) drilli...
Gespeichert in:
Veröffentlicht in: | Knee Surgery and Related Research, 33(0) 2021, 33(0), , pp.13-13 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Notchplasty is a surgical technique often performed during anterior cruciate ligament reconstruction (ACLR) with widening of the intercondylar notch of the lateral distal femur to avoid graft impingement. The purpose of this study was to correlate femoral-tunnel length with 3-dimensional (3D) drilling angle through the anteromedial (AM) portal with and without notchplasty.
Computer data were collected from an anatomical study using 16 cadaveric knees. The anterior cruciate ligament (ACL) femoral insertion was dissected and outlined for gross anatomical observation. The dissected cadaveric knees were scanned by computed tomography (CT). Three-dimensional measurements were calculated using software (Geomagic, Inc., Research Triangle Park, NC, USA) and included the center of the ACL footprint and the size of the ACL femoral footprint. The femoral-tunnel aperture centers were measured in the anatomical posterior-to-anterior and proximal-to-distal directions using Bernard's quadrant method. The ACL tunnel was created 3-demensionally in the anatomical center of femoral foot print of ACL using software (SolidWorks®, Corp., Waltham, MA, USA). The 8-mm cylinder shaped ACL tunnel was rested upon the anatomical center of the ACL footprint and placed in three different positions: the coronal plane, the sagittal plane, and the axial plane. Finally, the effect of notchplasty on the femoral-tunnel length and center of the ACL footprint were measured. All the above-mentioned studies performed ACLR using the AM portal.
The length of the femoral tunnels produced using the low coronal and high axial angles with 5-mm notchplasty became significantly shorter as the femoral starting position became more horizontal. The result was 30.38 ± 2.11 mm on average at 20° in the coronal plane/70° in the axial plane/45° in the sagittal plane and 31.26 ± 2.08 mm at 30° in the coronal plane/60° in the axial plane/45° in the sagittal plane, respectively, comparing the standard technique of 45° in the coronal/45° in the axial/45° in the sagittal plane of 32.98 ± 3.04 mm (P |
---|---|
ISSN: | 2234-0726 2234-2451 1225-1623 2234-2451 |
DOI: | 10.1186/s43019-021-00092-5 |