Separation of Hot Particulate from a PFC Decontamination Solution for Reuse by Filtration Equipment

Recently, PFC (perfluoro carbonate) decontamination technology was found to be excellent for the removal of smaller sizes of hot particulate from a hot cell. Due to the high cost of a PFC solution, it is necessary to purify it and reuse it for the next decontamination process. This study presents th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of industrial and engineering chemistry (Seoul, Korea) 2006, 12(4), , pp.531-539
Hauptverfasser: Gye-Nam Kim, Mathuresh Narayan, 원휘준, Wang-Kyu-Choi?, Chong-Hun Jung
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Recently, PFC (perfluoro carbonate) decontamination technology was found to be excellent for the removal of smaller sizes of hot particulate from a hot cell. Due to the high cost of a PFC solution, it is necessary to purify it and reuse it for the next decontamination process. This study presents the results of a hot particulate separation from a contaminated PFC solution by the manufactured filtration equipment. SEM (Scanning Electron Microscope) results showed that contaminated hot particulates was present in the PFC solution, and their size ranges were from 0.2 to 10 m, however, the radioactive level of the PFC solution was very high. Ceramic filter was found to be highly stable with the high alpha radioactivity. The equipment mainly consisted of two sizes of filters, 1.4 m primary filter and 0.2 m final filter. Removal efficiency of these filters was found to be more than 99 %. Turbidity of the PFC solution increased with the particulate concentration. Turbidity and pressure play a significant role in the removal efficiency. The removal efficiency initially was slightly low at a high pressure, but it gradually increased with the time, the change was found to be greater when the turbidity was high. At a low pressure and a high concentration, the removal efficiency was relatively high and remained constant with time. At a high pressure and a high concentration, the removal efficiency in the beginning was low but it gradually increased with time. The flux was high at high pressure for individual filters, and it slightly decreased with time but in the case of the final filter this change was a little high. When the experiment was executed with both filters insitu, the flux remained constant. KCI Citation Count: 1
ISSN:1226-086X