Continuous and Accurate PCRAM Current-voltage Model
In this paper, we propose a new Verilog-A current-voltage model for multi-level-cell PCRAMs. This model can describe the PCRAM operation not only in full SET and RESET states but also in the partial resistance states. And, 3 PCRAM operating regions of SET-RESET, Negative Differential Resistance,and...
Gespeichert in:
Veröffentlicht in: | Journal of semiconductor technology and science 2011, 11(3), 43, pp.162-168 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, we propose a new Verilog-A current-voltage model for multi-level-cell PCRAMs.
This model can describe the PCRAM operation not only in full SET and RESET states but also in the partial resistance states. And, 3 PCRAM operating regions of SET-RESET, Negative Differential Resistance,and strong-ON are unified into one equation in this model thereby any discontinuity that may introduce a convergence problem cannot be found in the new PCRAM model. The percentage error between the measured data and this model is as small as 7.4% on average compared to 60.1% of the previous piecewise model. The parameter extraction which is embedded in the Verilog-A code can be done automatically. KCI Citation Count: 4 |
---|---|
ISSN: | 1598-1657 2233-4866 |
DOI: | 10.5573/JSTS.2011.11.3.162 |